Buttons and Indications 

 
The controller will perform  a hardware reset when the Reset Button is toggle. 
The Service button is used to activate the built-in bootloader program for software upgrade.  
Each digital output has a correspondence LED to indicate its current state. 

 

Button and LED indications 

 

 

 

LED Conditions 

Description 

 

PWR 

PWR is used to indicate the presence of 
24VAC power source, and internal power 

 

ERR 

ERR is to indicate whenever there is 
communication errors. 

 

STS 

STS is used to indicate the heartbeat of the 
Microcontroller. The STS LED will blink at 
1-second interval in normal operation 
condition. 

 

TXRX 

TXRX is used to indicate when there are 
communication activities (Transmitting or 
Receiving) on the communication port. 

 

Technical Support 

 
For technical issue, please contact 
 
Worldwide and Asia Pacific Support 

[email protected]

  

Americas Support 

 

 

[email protected]

  

Europe Support   

 

 

[email protected]

  

 
 

 

Содержание FD-20i Series

Страница 1: ...EasyIO FD 20i User Reference v1 2 EasyIO FD 20i Series User Reference...

Страница 2: ...EasyIO FD 20i User Reference v1 2 Document Change Log 1st June 2019 Document created 18th June 2019 Update power supply details 18th March 2020 Updated the temp table selection...

Страница 3: ...IO logo are registered trademarks of EasyIO Holdings Pte Ltd CPT Tool is by Online Tools Inc BACnet and ASHRAE are registered trademarks of American Society of Heating Refrigerating and Air Conditioni...

Страница 4: ...ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer o...

Страница 5: ...r Reference v1 2 Contents Introduction 6 Hardware Configurations 7 Power supply Connection 7 RS485 Connection 8 Universal Input Connection 10 Digital Input Connection 10 Buttons and Indications 12 Tec...

Страница 6: ...IO FD 20i Series controller comes with built in bootloader program Built in bootloader program will enable user to upgrade firmware without sending back to factory EasyIO FD20 do not have an Ethernet...

Страница 7: ...se individual power supply for each controller If a single power supply is used make sure controller power supplies are connected with the same polarity Electrical Characteristic Power Supply 24V AC 5...

Страница 8: ...RS485 device make sure all devices are having the same ground connection Make sure you are connecting the same wire for the same terminal position all H terminals connected to the same wire Daisy Chai...

Страница 9: ...The white the spot white square represent the DIP switch toggle button EasyIO FC 20 enlarged DIP switch Setting DIP switch number Functions Remarks 1 Protocol Setting On Bacnet MSTP Off Modus RTU 2 S...

Страница 10: ...0K with Shunt Temperature table selection Temperature table selection is via BACnet objects or Modbus register By default each UI channel temperature table is set to table 1 Table Number Temperature T...

Страница 11: ...nput Terminal Digital Imput Block Channel DI 1 DI 1 DI 2 DI 2 DI 3 DI 3 DI 4 DI 4 DI 5 DI 5 DI 6 DI 6 DI 7 DI 7 DI 8 DI 8 DI 9 DI 9 DI 10 DI 10 UI1 DI 11 UI2 DI 12 UI3 DI 13 UI4 DI 14 UI5 DI 15 UI6 DI...

Страница 12: ...d to indicate the presence of 24VAC power source and internal power 2 ERR ERR is to indicate whenever there is communication errors 3 STS STS is used to indicate the heartbeat of the Microcontroller T...

Отзывы: