background image

INxx_xxxxxx_yyww

RCJ35EN5001A01

1,5A

1,5A

L

T2

T1

Safety Advice

 

 

Before installing the device, carefully 

read through this operating manual! Fai-

ling to observe these instructions may 

result in fire or other hazards.

  -   The electrical installation may  

only be performed by an autho- 

rised and qualified electrician.

 -  The load current circuit on which the 

device is operated must be protected by a 

circuit breaker switch in accordance with 

EN60898-1 (tripping characteristic B or C, 

max. 5 A rated current). 

 -  We will not accept any liability for personal 

injury or damage to property caused by 

failure to observe the operating instructions 

and in particular the safety advice!

 -  Observe the applicable laws, standards and 

regulations as well as the manufacturer’s 

instructions for the devices to be operated!

 -  Have faulty units checked by the manufactu-

rer!

 -  Do not open the unit housing!

 -  Do not make any unauthorized alterations or 

modifications to the unit!

Function

Using  the  bidirectional  flush-mounted  receiver 

RCJ35,  a  tubular  motor  can  be  controlled  via    

Easywave transmitters or via two button inputs. 

32 transmission codes can be programmed into  

the receiver.

The RCJ35 is equipped with operating modes 

UP/DOWN, UP/STOP/DOWN and SEQUENCE. 

The „slat adjustment“ function is also available 

as an option, whereby the motor is controlled in 

DEAD MAN mode for the first 2 seconds of trans

-

mitter actuation and only then switches to self-

retaining.

The runtime of the motor can be set separately 

for each movement direction. The runtime is 90 

seconds each ex-factory.

The  integrated  POTA  (Programming  Over  The 

Air) remote programming function can be used to 

reprogram an already-installed and no longer ac-

cessible receiver. A detailed POTA programming 

manual is available on our website:             

https://www.eldat.de/pota_en.pdf

or you can request support from our customer 

service.

Push-button inputs T1 and T2 

The RCJ35 has two push-button inputs (T1 and 

T2), which have to be connected to

 

L

.

In the factory state, the button inputs operate in 

the UP/DOWN 2-button operation mode without 

slat adjustment. The external buttons can be pro

-

grammed in a different operating mode or deleted 

at any time. This is done in the same way as pro

-

gramming Easywave transmitters.

If an external push-button is deleted, it operates 

again in the ex-factory operating mode.

Button input T1 behaves like a transmitter button 

with button code A; button input T2 behaves like 

button code B. 

In 1-button and 2-button operation, the movement 

command  is  carried  out  by  briefly  pressing  the 

connected buttons. 

In 3-button operation, the buttons or switches 

must remain pressed for the desired period of 

movement. As long as a button input is active, no 

transmitter commands are accepted in the 3-but-

ton operation.

RCJ35EN5001A01  

Wiring diagram

Wire cross-sections

Only wires with a cable cross-section of 0.5 mm² 

to  2.5 mm²  shall  be  connected.  The  stripping 

length of the connecting wires is 6 to 7 mm.

Technical Details

Frequency: 

868.30 MHz

Radiated power: 

6.38 mW

Modulation:  

FSK

Coding:  

Easywave neo

 

POTA

Device type: 

motor control

Power supply: 

230 V AC, 50 Hz

Input: 

2 external buttons

Output: 

2 potential-loaded relay  

 contacts 

(normally open)

Power consumption: 

0.4 W standby

 

0.8 W max. w/o load

Maximum contact load

- resistive load cosφ = 1.0

      

5 A / 1,150 VA

- inductive load cosφ = 0.8 

1.5 A /    345 VA

 

Operating temperature:  -20 °C to +45 °C

Dimensions (H/W/D):   43.0 / 42.0 / 17.5 mm

Weight: 

approx. 31 g

Scope of Delivery

Flush mounted receiver RCJ35, 

 

operating manual

Intended Use

The device may only be used to control tubular 

motors and only indoors! It is operated using Ea-

sywave radio transmitters or external buttons.

The manufacturer will not be liable for damage 

caused by improper or inappropriate use.

RCJ35   Flush-mounted receiver   230V Motor potential-loaded

EN

Models

Programming 
Button 

P

Operation

Briefly  press  button 

P

 to begin programming 

mode for the required operation type. Any Easy

-

wave transmitter can then be programmed under 

this operation type. Each transmitter can be as

-

signed its own operating mode. A separate ope

-

ration type can be assigned to each transmitter /  

transmitter button. For local operation, 2 external 

buttons can be connected.

2-button-operation

In this operating mode, movement commands 

are triggered by 2 related transmitter buttons. The 

movement is stopped by pressing the button for 

the opposite direction. Only one transmitter but

-

ton must be programmed, the code for the asso-

ciated button is assigned automatically.

3-button-operation

In 3-button operation, movement commands and 

the stop command are each triggered by a se-

parate transmitter button. This operating mode is 

therefore particularly suitable for central control 

and the use of repeaters.
A transmitter with at least three associated but

-

tons  is  required.  Only  one  of  these  transmitter 

buttons must be programmed into the receiver,the 

code for the corresponding buttons is assigned 

automatically. 

1-button-operation

Using a single transmitter button, move and stop 

commands  are  triggered  in  a  defined  sequence 

each time it is pressed. 
A transmitter with four buttons (A, B, C, D) could 

therefore  be  used  to  control,  e.g.  four  different 

devices. 

Timeout

 

(1)

If no button is pressed within 30 seconds, the 

RCJ35 automatically switches to operation mode. 

The settings are not saved.

Operating modes

2-button-operation

UP/DOWN

 

Transmission code A or C    

Transmission code B or D    

Roller shutter UP 

Roller shutter DOWN

STOP with opposite direction button 

optionally with slat adjustment

3-button-operation

UP/STOP/DOWN

 

Transmission code A            

 

Transmission code C or D    

Transmission code B            

Roller shutter UP

Roller shutter STOPS

Roller shutter DOWN

optionally with slat adjustment

1-button-operation

SEQUENCE

  

Transmission code

 A/B/C/D 

The roller shutter executes movement commands one 

after another:
UP 

 STOP 

 DOWN 

 STOP 

 UP 

→ ...  

LED P 
red|green

 

230 V AC  

50 Hz

N

L

1,5

1,5

µ

µ

L

T2

N

L

T1

Отзывы: