Tolerance indicators
Values within tolerance are green. Values not within tolerance are red. The tolerance indicators are visible for a while.
To show them after they have disappeared, simply tap the vertical or horizontal value.
Indicates the tolerance level "good".
Indicates the tolerance level "excellent".
Indicates not within tolerance.
Show Gap
By default, angular error/100 mm is displayed. To show gap, you need to set the coupling diameter. See "Coupling dia-
meter" on page 36
To show the result as gap, tap
and
.
Offset and angle values
The offset and angle value indicate how well the machine is aligned at the coupling. They appear in both horizontal
and vertical direction. These values are important to get within tolerance.
Offset:
The center lines of two axis are not concentric but parallel. This is measured at
the coupling centers. In this example, a negative offset is shown.
Angular misalignment:
The center lines of two axis are not parallel. In this example, a positive angle is
shown.
Offset and angular misalignment:
Misalignment is often a combination of both offset and angular misalignment.
Result table
In the Result view, tap
to display the table view.
50
HORIZONTAL
Содержание XT11
Страница 1: ...User Manual English 05 0835 EN Revision 2 0 User Manual last built 9 12 2017...
Страница 2: ......
Страница 6: ...This page intentionally left blank to ensure new chapters start on right odd number pages...
Страница 32: ...32...
Страница 58: ...A Offset B Angular C Both offset and angular misalignment 58 BELT...
Страница 65: ...A Misaligned sheave B Aligned sheave the laser beam disappears in the slot of the target 65 BELT...
Страница 74: ...Part No 12 0985 Camera removed from XT11 74 TECHNICAL DATA...
Страница 76: ...Part No 12 0968 IR Camera added to XT11 Part No 12 0985 Camera removed from XT11 76 TECHNICAL DATA...