English

05-0461 Revision 13

System version 11.0

E710

Содержание E710

Страница 1: ...MANUAL English 05 0461 Revision 13 System version 11 0 E710...

Страница 2: ......

Страница 3: ...date 18 License 20 Bluetooth set up 21 CHOOSE PROGRAM 23 Preparations 23 PROGRAM VALUES 25 Tolerance 26 Zoom 26 Halve or Zero set value 27 Live values colours 27 Automatic recording 28 Precision level...

Страница 4: ...ARTIAL FLANGE FLATNESS 105 Measure 107 Result 108 FLANGE FLATNESS SECTION 109 Preparations 110 Measure 111 Rotate flange 111 PARALLELISM A 113 Prism set up 114 Precision level 115 Calibrate the precis...

Страница 5: ...is subject to the following two conditions 1 this device may not cause harmful interference 2 this device must accept any interference received including interference that may cause undesired operatio...

Страница 6: ...Damalini is not included in the warranty Note Before delivery of the product for warranty repair it is the responsibility of the buyer to backup all data Data recovery is not included in the warranty...

Страница 7: ...ice and calibration Our Service centres will quickly assist you if your measurement system need to be repaired or when it is time for calibration Our main Service centre is located in Sweden There are...

Страница 8: ...D75 Compatibility The E series is not compatible with previous analogue units from the D series You can however continue to use previous brackets Disclaimer Damalini AB and our authorized dealers wil...

Страница 9: ...ystems C External connection Use for projector for example Not available on all systems D USB A master Use for USB memory E USB B slave Use for connecting to a PC F Connection for Easy Laser equipment...

Страница 10: ...ay Press to select the currently selected icon for example Function buttons The icons above the function buttons change depending on which view is currently displayed on screen Below is a list of the...

Страница 11: ...en the coordinates has been rotated in the detector Go to Control panel to rotate coordinates Hourglass The Display unit is in the middle of a task Display unit charging Indicating that a power adapto...

Страница 12: ...le handling on page 11 LED lights Right indicator Yellow Flashing The internal battery in the Display unit is charging Left indicator Left indicator has several functions and colours Red Blue Quick fl...

Страница 13: ...you have this connection you can open the files in the Display unit via the explorer in your PC However the Display unit is locked Dry cell batteries When you get a battery warning insert four R14 dr...

Страница 14: ...enu Use OK button as equal sign Unit converter The unit converter is found on the Start view and Control panel 1 Select and to open Unit converter 2 Select a category Move using the navigation buttons...

Страница 15: ...which program the file was saved Press to open a measurement file Function buttons Back to previous view Report on page 14 Open file as template on page 13 Print file Optional on page 14 Sort files al...

Страница 16: ...the selected file as a Favourite 3 Go to the start screen and select to see all favourites 4 Press to open a Favourite All distances are filled in Import favourites The favourite files are saved in th...

Страница 17: ...i archive Barcode Save file with barcode The barcode scanner is not included in all systems The first time you measure a machine you stick a barcode on the machine and save the measurement together wi...

Страница 18: ...your logo logo jpg The default logo has the proportions of 230x51 pixels 2 Connect the Display unit to your PC using the USB cable 3 Place your image in the Display unit s folder Damalini custom repor...

Страница 19: ...vailable to the statistical filter Selected filter Measurement progress Time is depending on which filter you have selected Select filter Use as short a time as possible that still produces acceptable...

Страница 20: ...0 only 0 01mm is possible Detector rotation Personal setting The coordinate system can be rotated 90 Select to open the Detector rotation view When you have rotated the coordinates a warning is displa...

Страница 21: ...ht Personal setting Select to open the Backlight view Use the navigation buttons to move between the fields Press to save changes When backlight is off the left LED signal will flash to indicate that...

Страница 22: ...r off view Note Measurements in progress will not be saved in the event of an Automatic power off Information Select to display the information regarding serial number and version of the equipment Inf...

Страница 23: ...menu is displayed Note During restart the screen turns black for up to one minute When the main menu is displayed it can freeze no response when you press buttons If this happens press the On Off butt...

Страница 24: ...USB 1 Save the downloaded license file to a USB memory stick 2 Insert the USB memory stick in the Display unit 3 Select and to display the License view 4 Select to search for licenses 5 Press to impor...

Страница 25: ...ti cally be connected when you start a measurement program 5 Press to save changes and to leave the Bluetooth view 6 Enter a measurement program The Display unit will connect to the selected units Whi...

Страница 26: ...to use to 4 Make sure that the other units are set to 5 Enter a measuring program The Display unit will connect to the selected unit This may take a couple of minutes Note Remove Bluetooth unit from t...

Страница 27: ...units Straightness For straightness measurement of machine bases bearing journals machine tools etc BTA For alignment of belt and chain drives Offset and Angle Shows centre offset and angular error b...

Страница 28: ...24...

Страница 29: ...eport on thermal printer optional equipment See Streaming values on page 29 Set current value to zero Halve displayed value Return to absolute value Only available after zeroing or halving Choose how...

Страница 30: ...tons to move between the fields and to change the tolerance 3 Press OK Live values and marking displayed in green when within tolerance Live values displayed in red when outside tolerance Zoom 1 Selec...

Страница 31: ...elect to half displayed value Zero point of the PSD moves halfway towards the laser point Zero set value Select to zero set displayed value Zero point of the PSD moves to the laser point Absolute valu...

Страница 32: ...display the current values As default a target and a table is displayed but you can choose to show only target for example Select to display the different layout options see image below Note Use left...

Страница 33: ...r See USB Se rial Port under Ports COM and LPT 2 Click Open 3 Start the program Values in the Display unit 4 Select and to start streaming values 5 To stop select In this example PuTTY is used to show...

Страница 34: ...detec tor 8 Place the shim under the magnet base of the S unit The S unit s reading shall correspond to the move ment within 1 1mil 1digit 0 01mm 1 digit Note The shim must be exactly 1 mm In this exa...

Страница 35: ...Thermal compensation on page 42 9 12 3 The measuring positions are registered at positions 9 12 3 o clock The inclinometers are not used Measure using 9 12 3 on page 38 Note Measurements made with ol...

Страница 36: ...ay unit is equipped with Bluetooth wireless technology which makes it pos sible for the Display unit to receive data without using cables For more information see Bluetooth set up on page 21 Adjust me...

Страница 37: ...you need on the machines More than three feet pairs are visualized as one solid foot on the machine Switch M and S 1 Use navigation buttons up and down to find the machine you want 2 Press The next ma...

Страница 38: ...Distance between feet pair one and feet pair two Coupling diameter Optional select to activate field Function buttons Leave program See Control panel on page 15 See Tolerance on page 44 See Thermal c...

Страница 39: ...st position The first position is automatically set to zero A red marking is displayed 3 Turn shafts outside of the red 20 marking 4 Press to register second position 5 Turn shafts outside of the red...

Страница 40: ...easurement points For a more accurate result try to spread the points as much as possible The colours indi cates where the optimum positions to measure are The colour bar indicates a statistical accur...

Страница 41: ...points as much as possible Acquired accuracy Actual measured values from the units If the acquired accuracy is low it may depend on for example air turbulence or bearing clearance Temperature stabili...

Страница 42: ...ition The first position is automatically set to zero 5 Turn shafts to 12 o clock 6 Press to register second position 7 Turn shafts to 3 o clock 8 Press to register third position The Result and adjus...

Страница 43: ...w the measuring units are positioned Print report on thermal printer optional equipment Available when you open a saved measurement Edit distances Press to confirm changes The result is recalculated S...

Страница 44: ...xis are not concentric but parallel This is measured at the coupling centres In this example a positive offset is shown Angular misalignment The centre lines of two axis are not parallel In this examp...

Страница 45: ...9 12 3 or 6 o clock Select to show the Position indicator Position indicator Function buttons Toggle button Show hide position indicator manually Toggle button Select to display the position indicator...

Страница 46: ...e compensate with 5mm in COLD condition 1 3 Indicates that the compensation values are set for cold offline condition Vertical offset and angle for movable machine Indicates that thermal compensation...

Страница 47: ...pair on the stationary machine you need to enter distances 1 Select and 2 The RefLock graph view is displayed Navigate using the left and right navigation button 3 Select to lock the selected feet pa...

Страница 48: ...rol panel on page 15 Edit user defined tolerance Delete user defined tolerance Add new tolerance You can add your own user defined tolerance 1 Select the row Add new tolerance Press 2 Enter name and t...

Страница 49: ...0 03 3 0 0 07 3000 4000 1 0 0 02 2 0 0 04 4000 5000 0 5 0 01 1 5 0 03 5000 6000 0 5 0 01 1 5 0 03 Angular misalignment Excellent Acceptable rpm mils mm 100mm mils mm 100mm 0000 1000 0 6 0 06 1 0 0 10...

Страница 50: ...46 Horizontal...

Страница 51: ...u need to enter distances between the feet pairs The measure view is displayed 3 Select Softfoot is only available before you have registered any measurement points Function buttons Leave program See...

Страница 52: ...nt 9 Do a Softfoot check again Result Arrow indicating that the machine is tilting in this direction Measure Loosen and retighten bolt before register value Note If the largest movement is opposite fr...

Страница 53: ...IN Use for machines mounted in a train with two or more couplings Work flow C o n t i n u e u n t i l y o u h a v e m e a s u r e d a l l c o u p l i n g s Adjust Build machine train Enter distances M...

Страница 54: ...ve 1 Use navigation buttons to select Basic or Custom 2 Press Basic Three predefined machines Custom Build a custom train Basic The basic machine train contains a pump a gearbox and a motor These thre...

Страница 55: ...and down to find the machine you want 2 Press The next machine becomes active 3 Add as many machines as you need When you are done select to continue to Measure view Select number of feet pair If you...

Страница 56: ...stead of angle Continue to Measure view 1 3 4 5 2 6 7 1 3 4 5 2 6 7 Distance between first and second feet pair Distance between S unit and M unit Measure between the rods Distance between second feet...

Страница 57: ...on The Result and adjust view displayed 7 The result is displayed You can show the result as graph table or machine view See chapter Result 8 From the result view select to measure next coupling If yo...

Страница 58: ...d the measurement points For a more accurate result try to spread the points as much as possible The colours indicates where the optimum positions to measure are The colour bar indicates how statistic...

Страница 59: ...ster third position 9 The result is displayed You can show the result as graph table or machine view See Result on page 56 10 From the result view select to measure next coupling If you want to adjust...

Страница 60: ...upling Select the machine you want to adjust and press See Adjust on page 60 Function buttons Remeasure the coupling Press and hold to leave program See Control panel on page 15 Save file Measurement...

Страница 61: ...handling on page 11 Toggle button Show Gap or Angle values Lock unlock feet pair Available when you show feet values See Lock feet pair on page 59 Toggle between showing feet or coupling values Switc...

Страница 62: ...ge 56 Lock unlock feet pair If you can not adjust a feet pair use the lock function See Lock feet pair on page 59 Toggle between showing horizontal or vertical graph Switch result view Available when...

Страница 63: ...ulated Manual fit Only available when you have measured the whole train and only in graph view Use this function when you know that you for example can move a machine a little in one direction but not...

Страница 64: ...just measured the coupling the Adjustment view is displayed If not you need to remeasure the coupling first and the Measure view is displayed 2 Adjust the machine 3 Select when you are done The Measur...

Страница 65: ...icator on page 41 See Live values on page 40 Continue You need to remeasure the coupling to confirm the position of the measuring units Uncertain coupling When you adjust one coupling it might affect...

Страница 66: ...ge 15 Edit user defined tolerance Delete user defined tolerance Add new tolerance You can add your own user defined tolerance 1 Select the row Add new tolerance Press 2 Enter name and tolerance 3 Pres...

Страница 67: ...reader simply scan the barcode and all machine data is read See Measurement file handling on page 11 Function buttons Leave program See Control panel on page 15 Select to enter diameter of coupling F...

Страница 68: ...y set to zero 3 Turn units to position 12 o clock 4 Press to register position 5 Turn units to position 3 o clock 6 Press to register position Measurement result is displayed Circle indicates where to...

Страница 69: ...file handling on page 11 Set tolerance Show target This is a quick way to see where the laser beam hits the target and how the measuring units are positioned Print report on thermal printer optional...

Страница 70: ...00 Values below zero indicates that the bolt is low and need shimming 3 Select to return to Result view Note If you shim the machine remeasure from position 9 o clock to update all measurement values...

Страница 71: ...irectly on the flange 2 Mount the S unit on the arm bracket 3 Mount the M unit on the magnetic disc If the adjustable shaft has a thread use suitable search dowel This makes the centering easier 4 Mou...

Страница 72: ...ch it can be difficult to cone the laser beam If this is the case proceed to Rough alignment 1 Note where the laser beam hit the target at position 1 2 Turn one of the shafts 180 Note the position 2 3...

Страница 73: ...beams to the marking for centre of detector 6 Remove the targets The Display unit shows the position of the laser beams Measure The shafts are positioned at 9 o clock 1 Press OK to register first pos...

Страница 74: ...Available when you open a saved measurement Toggle button Show vertical or horizontal live values Toggle button to move the lock By default the feet pair with the highest value is set to zero and loc...

Страница 75: ...ghly aligned along the measurement object The detector is then positioned on the selected measuring points and the values registered Work flow Select and to start the Straightness program Measure Resu...

Страница 76: ...ence points Function buttons Zero set displayed value Only zeroes the value while the target is opened Return to the absolute value Halve displayed value Only zeroes the value while the target is ope...

Страница 77: ...ons Leave program See Control panel on page 15 See Straightness settings on page 84 Show target Show reference target Edit distance Edit distance for selected point Add measuring point Delete measurin...

Страница 78: ...er of measuring points Press Select if the points are evenly placed or not Use navigation buttons left and right If set to YES you are prompted to fill in the distance between point 1 and 2 If set to...

Страница 79: ...measuring point Adding points between renumbers the existing following points In this example we add a new point after point number three 550 1 2 3 4 4 5 5 6 Delete measuring point Deleting points bet...

Страница 80: ...in printer optional equipment Save report only when you have opened a saved measurement Set tolerance It is possible to set different vertical and horizontal toler ance See Tolerance on page 79 Zoom O...

Страница 81: ...Peak peak Difference between Max and Min value Standard deviation Average difference between Max and Min value Straightness RMS Root Mean Square Numerical Flatness Max waviness Set waviness is shown i...

Страница 82: ...t History points Zoom It is possible to zoom in the graph view if you have registered more than 20 points Select a measurement point and select and The graph is zoomed in around the selected point Sel...

Страница 83: ...ph view vertical and horizontal tolerances are colour coded Predefined tolerance There are two ISO standard tolerances The ISO tolerance is calculated automatically depending on which distances you ha...

Страница 84: ...two reference points To remove a reference point select it in the table or graph and then select The point itself is not removed The reference points are clearly displayed in both table and graph Note...

Страница 85: ...n between the two set reference points Both reference points are set to zero Reference point with offset By using reference point offset it is possible to move the position of a reference point This c...

Страница 86: ...ven tolerances The difference between the best fit operations is the offset that is set Best fit around 0 This operation removes all ref erence points Centre the values so that the maximum and mini mu...

Страница 87: ...er than the second In many applications a smooth measurement is desired Using waviness it is possible to indicate the smoothness of a measurement In this example the rougher measure ment will get a wa...

Страница 88: ...able when you use the program Straightness with a two axis detector Show history If you remeasure a point the old values are saved as history points You can select to show or hide these points while m...

Страница 89: ...hen set to Smooth the graph will find a smooth path between the measurement points Smooth Sharp Waviness settings 1 Select A window is opened 2 Select waviness factor Navigate using the navigation but...

Страница 90: ...86 Straightness...

Страница 91: ...t number three 3 9 Adjust the laser beam by using the screw B on the tilt table Level to 0 1 mm Repeat procedure until you have all three reference points within 0 1 mm Enter distances Up to 500 measu...

Страница 92: ...delete the last point in the list Toggle button Enter distances for X or Y axis Continue to Measure view Note It is also possible to enter distances in the default distance view and switch to Distanc...

Страница 93: ...ction Measure left to right or up and down Show target Useful if you want to rough align for example Continue to Result view Available when you have measured three positions Tolerance By default the I...

Страница 94: ...easurement file handling on page 11 Toggle button Set selected point as reference point Remove as reference See Calculation settings on page 92 Raw data Revert to original data Three reference points...

Страница 95: ...3D Select and to open 3D view Only available when all points have been measured Use the navigation button to select measurement points Navigate using the numeric buttons Buttons 2 4 6 and 8 rotates t...

Страница 96: ...ou select a second reference point the values are not recalculated Set a third reference point to recalculate the values 3 Select if you want to return to raw data Set three reference points 1 Select...

Страница 97: ...rk to ensure that you place the detec tor exactly on the same position each time 5 Place the M unit on measurement position A 6 Select to zero set the value 7 Move the M unit to measurement point D Ad...

Страница 98: ...94 Twist Result Three measurement points are automatically set to zero Function buttons Remeasure Save file Measurement file handling on page 11 See Control panel on page 15...

Страница 99: ...e laser beam hits the centre 5 If you use a measurement program select to zero set point number one Point two 6 Move the detector to point number two see image 7 Adjust the laser beam by turning the s...

Страница 100: ...to enter this and get the number of measuring points Start angle As default the first measurement point is set to 0 Select a start angle if you want to start somewhere else Function buttons Back Leav...

Страница 101: ...ion buttons Back Press and hold to leave program completely Open Control panel Skip point Only available when it is possible to skip the selected point Some measurement points are mandatory to ensure...

Страница 102: ...tness RMS Root Mean Square Numerical Flatness Function buttons Remeasure Open Control panel Save See Measurement file handling on page 11 Alter flange diameter See Tolerance on page 104 Print on therm...

Страница 103: ...Flange graph view Select and to display the Graph view In this view you have a good overview of the result Use the navigation buttons to move in the graph Same function buttons as in Flange table vie...

Страница 104: ...press 3 Select one or three reference points When you select a second reference point the values are not recalculated Set a third reference point to recalculate the values 4 Select if you want to retu...

Страница 105: ...round zero Select and to calculate best fit around 0 Select one or all circles Note You can save reports with different settings for best fit to analyze further later Best fit calculated on circle A T...

Страница 106: ...t and to calculate the best fit with all measurement points above 0 Select one or all circles Best fit all negative The flange is tilted as in a Best fit calculation but the reference line is moved to...

Страница 107: ...Result view select and or As default the taper value of outer circle minus inner circle is displayed To calculate a different taper value select Taper table Select and to display Taper table Here you...

Страница 108: ...n Taper and or Best fit 1 Select and 2 Enter tolerance values for Best fit and or Taper 3 Turn the tolerance on off by Tolerance is displayed both in graph and table view Activate deactivate tolerance...

Страница 109: ...reparations Ensure a good measurement environment Strong sunlight warning lights vibra tions and temperature gradients can affect the readings Make sure the surface is clean Use the program Values Fla...

Страница 110: ...o enter this and get the number of measuring points Start angle As default the first measurement point is set to 0 Select a start angle if you want to start somewhere else Function buttons Back Leave...

Страница 111: ...t Available when you have measured enough points Start angle and first measurement If you do not want to start to measure where the start angle is simply use the naviga tion buttons to move to where y...

Страница 112: ...ce points automati cally See Reference points on page 100 Best fit When you perform a best fit calculation the flange is tilted to the lowest peak to peak value It is fitted as flat as possible betwee...

Страница 113: ...ou can measure 1 to 5 circles of measurement points for example inner middle and outer circles in order to see the taper of the flange Each circle can have 16 180 mea surement points The program guide...

Страница 114: ...ds on which measurement direction you have chosen Follow the instructions on screen 2 Rotate flange Note the direction on the screen 3 Mount the laser transmitter and a laser target as shown on screen...

Страница 115: ...ack to remea sure Filter The filter is increased by two steps when measuring merge points It is possible to override this See Filter on page 15 Note The merge points are analyzed and if uncertain poin...

Страница 116: ...select three reference points automati cally See Reference points on page 100 Best fit When you perform a best fit calculation the flange is tilted to the lowest peak to peak value It is fitted as fl...

Страница 117: ...the laser correctly The ref erence line is often a line alongside the machine but can also be a fixed object in the machine 1 Mount the laser on the same height as the prism 2 Level the laser accordi...

Страница 118: ...Repeat 3 and 4 until the beam is centered on the target in both outer and inner position 6 Switch the prism in tighten the locking knob and measure Now the angular prism can be moved to a new position...

Страница 119: ...ion 2 Press and select Calibration 3 Wait approx 15 seconds until the value has stabilized Press 4 Rotate the Precision level 180 5 Wait approx 15 seconds until the value has stabilized Press The Prec...

Страница 120: ...s 3 Press to continue to Measure view or use navigation button to enter the dis tance between the adjustment points The distance between adjustment points is not mandatory If you leave the space empty...

Страница 121: ...see Unit and resolution on page 16 Function buttons Back to Distance view See Control panel on page 15 Skip measuring with the Precision level for all rolls It is possible to turn it back on again fr...

Страница 122: ...the second position 7 Press to register the second position The angle of the roll is displayed 8 Press to go to Result view Or select to adjust the roll From the result view select and to add a new r...

Страница 123: ...d roll before you can continue Detector angle The position of the detector affects the measurement value when measuring parallel ism Therefore it is important to place the detector at the same angle a...

Страница 124: ...ce Black no tolerance set H H In this example the roll has a positive horizontal value V V In this example the roll has a negative vertical value Horizontal values The horizontal value is measured wit...

Страница 125: ...asurement file handling on page 11 See Tolerance on page 122 Alter distance and or name on roll Turn the Precision level on off Toggle button Set selected roll as reference Or press Show Result table...

Страница 126: ...er than the minimum value When you use Metric mm two decimals is possible When you use Imperial inch foot four decimals is possible Tolerance in graph view Tolerance in table view It is possible to se...

Страница 127: ...metres The rolls can be mounted at different heights Mount the security strap 1 Unscrew the security strap lock 2 Place the end of the security strap in the hole 3 Screw the lock back in place Make su...

Страница 128: ...ue has stabilized Press 4 Rotate the Precision level 180 5 Wait until the value has stabilized Press The Precision level has been calibrated The calibration is saved even when the Precision level is s...

Страница 129: ...el the laser to H value 1mm m 4 Press and select Calibration 5 Select Horizontal and press to register a value 6 Place the bracket with detector under the roll C 7 Press to register a value 8 Press to...

Страница 130: ...than 45 degrees see image 1 Adjust the offset by moving the laser transmit ter 2 Adjust the laser transmitter to spirit level 3 Adjust the offset and angle When the value box is green it is OK to con...

Страница 131: ...alue is shown in degrees To change unit see Unit and resolution on page 16 Function buttons Back to Distance view See Control panel on page 15 See Switch measurement direction on page 128 Skip measuri...

Страница 132: ...rea to measure 2 Press to register measurement value The result view is displayed Switch measurement direction It is possible to switch measurement direction To ensure an accurate measurement when you...

Страница 133: ...the value cor responds to the measurement program Red area indicates misalignment both in vertical and horizontal direction Roll set as reference Green within tolerance Red not within tolerance Black...

Страница 134: ...ge 11 Tolerance on page 131 Alter distance and or name on roll Turn the Precision level on off Set selected roll as reference Or press See Move laser on page 132 Show Result table view Show Result sid...

Страница 135: ...to be greater than the minimum value When you use Metric mm two decimals are possible When you use Imperial inch foot four decimals are possible It is possible to set tolerance and then deactive it A...

Страница 136: ...and to add a new roll 6 Move the detector and measure the new roll Filter If the roll was measured with a filter lower than 5 a warning is displayed when you select Move laser You can choose to remeas...

Страница 137: ...Shaft or Geo systems but bought as an option For technical information see BTA E180 Optional on page 150 All types of sheave pulleys can be aligned regardless of belt type You can compen sate for she...

Страница 138: ...urning the other ones in Non magnetic sheave pulleys can be aligned as the units are very light and can be mounted using double sided tape 1 Mount the laser transmitter on the stationary machine 2 Mou...

Страница 139: ...fields if the sheaves have different face widths Contains a sub menu The Display unit automatically recognize where the units are placed However you can do this manually as well Set M unit to the lef...

Страница 140: ...See also Tolerance on next page Print on thermal printer Optional equipment Available when you have saved the measurement Edit distance Values colours White No tolerance set Green Value within toleran...

Страница 141: ...po sitioning one of the sheaves on its shaft Correct vertical angular error by shimming the movable machine Correct horizontal angular error by adjusting the movable machine with lateral jackscrews Wh...

Страница 142: ...to move up and down in the menu Press to switch position on the M and S unit Toggle between mm and inch with Battery Press to see the battery status of the detector While the battery is charging ther...

Страница 143: ...eration RMS in the frequency range between 3200 and 20000 Hz Trend analysis of the bearing condition value can be used to determine wear and tear of machine bearings Magnetic tip Measuring tip See Vib...

Страница 144: ...ister value Function buttons Leave program See Control panel on page 15 Save see Measurement file handling on page 11 Print report on thermal printer optional equipment Generate report Available when...

Страница 145: ...ith rated power above 15kW Guideline Another standard you can use is ISO 2372 class 4 for large machines on flexible foundations 0 3 mm s 0 0 12inch s Small vibrations None or very small bearing wear...

Страница 146: ...ions produced by a machine with a bearing fault The bearing condition value is the quadratic mean RMS value of all high frequency vibrations between 3200 Hz to 20000 Hz This value is an acceleration a...

Страница 147: ...g units 2 Press OK Vertical offset and angle displayed Horizontal offset and angle displayed Function buttons Leave program See Control panel on page 15 Show target This is a quick way to see where th...

Страница 148: ...144 Offset and angle...

Страница 149: ...ge 21 The Battery pack s serial number is placed on the backside This serial num ber is shown in the Bluetooth view in the Display unit When the Battery pack run empty the lights for Battery indicator...

Страница 150: ...adaptor to the splitting box Use the standard power adaptor delivered with your system All lights are lit up on the splitting box 2 Plug in the battery pack and Detectors to the splitting box Correspo...

Страница 151: ...xtension chains 2 Magnet bases 2 Offset brackets 1 Set of rods 4x60 mm 4x120 mm 4 72 2 36 1 Manual 1 Measuring tape 3 m 1 USB memory stick 1 USB cable 1 Power adaptor 100 240 V AC 1 Toolbox 1 Cleaning...

Страница 152: ...Normal operating cycle Connections USB A USB B External Easy Laser units Network Storage memory 100 000 measurements Help functions Calculator Converter Environmental protection IP Class 65 Housing ma...

Страница 153: ...ironmental protection IP Class 66 and 67 Dimensions BxHxD 60x60x42 mm 2 36x2 36x1 65 Weight 202 g 0 45 lbs Internal battery LI Po 3 7 volt 2 5Wh 680mAh Wireless connection unit Not included for all sy...

Страница 154: ...ABS plastics Hard anodized aluminium Dimensions BxHxD 145x86x30 mm 5 7x3 4x1 2 Weight 270 g 9 52 oz Detector unit E180 Sheave diameter 60 mm 2 5 Displayed resolution Changeable between mm inch Axial...

Страница 155: ...suring tip Instrument Software Measurement range 0 50 mm s 0 2 inch s RMS Resolution 0 1 mm s 0 005 inch s Frequency range Total level 2 3200 Hz Lp 10 3200 Hz Hp Bearing condition 3200 20000 Hz Probe...

Страница 156: ...Connect to Display unit Connect the Precision level to the Display unit via Bluetooth Precision level E290 Resolution 0 01 mm m 0 0001 Range 2 mm m Measurement error Range 1mm m accuracy within 0 02mm...

Страница 157: ...oint 76 P PDF 11 16 Peak to peak 77 98 101 Personal settings 15 Position indicator 39 41 Power adaptor 9 Precision level 117 Print 14 Prism 118 Projector 7 Q Quickmode 74 R Raw data 90 Raw values 72 R...

Страница 158: ......

Отзывы: