35
Horizontal
Measure using Easy Turn™
Preparations
Follow the preparations as described in the previous pages.
1. Mount the measuring units.
2.
Enter distances, confirm each distance with
OK
.
3. If needed, perform a rough alignment.
4. If needed, perform a Softfoot check.
Measure
It is possible to measure with as little as 40º spread between the measurement points.
However, for an even more accurate result, try to spread the points as much as possi-
ble. The colours indicates where the optimum positions to measure are.
1. Adjust laser to the centre of the targets. If needed, adjust the units on the rods,
then use laser adjustments knobs.
2. Press
to register first position. The first position is automatically set to zero.
A red marking is displayed.
3. Turn shafts outside of the red 20º marking.
4. Press to register second position.
5. Turn shafts outside of the red markings.
6. Press to register third position. The Result and adjust view displayed.
Function buttons
Back
. Measure previous position or back to Distance view.
See
Switch to the EasyTurn™ method.
Switch to the 9-12-3 method.
Switch to the Horizontal Multipoint method.
See
Red 20º marking
First position is auto-
matically set to zero
Edge warning
Edge warning
When the laser beam is
close to the edge, the edge
is “lit up” as a warning. It
is not possible to register
values when you see the
edge warning.
Green indicates best
measurement position
Содержание E530