34
Horizontal
Enter distances
Confirm each distance with
.
3
3
5
2
7
1
6
1. Distance between first and second feet pair. Optional, select
to activate field.
2. Distance between second feet pair and S-unit. Optional, select
to activate field.
3. Distance between S-unit and M-unit. Measure between the rods.
4. Distance between S-unit and centre of coupling.
5. Distance between M-unit and feet pair one.
6. Distance between feet pair one and feet pair two.
7. Coupling diameter. Optional, select
to activate field.
Function buttons
Leave program.
See
.
See
See
“Thermal compensation” on page 40
.
Select to enter distances of the S-machine.
Toggle between showing Distance view in 3D or 2D.
Diameter
. Select to enter coupling diameter. This is necessary if you want
the result based on the gap of the coupling instead of angle.
Add a feetpair.
Toggle button. Show movable machine to the left or the right.
Continue to Measure view. Available when you have entered the manda-
tory distances.