SDM630Pulse

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

Measures kWh Kvarh, KW, Kvar, KVA, P,
F, PF, Hz, dmd, V, A, etc.

Bi-directional measurement IMP & EXP

Two pulse outputs

Din rail mounting 35mm

100A direct connection

Better than Class 1 / B accuracy

USER MANUAL

2014 V1.0

Содержание SDM630Pulse

Страница 1: ...x 0086 573 83698883 Web www eastron com cn SDM630Pulse DIN Rail Smart Meter for Single and Three Phase Electrical Systems Measures kWh Kvarh KW Kvar KVA P F PF Hz dmd V A etc Bi directional measurement IMP EXP Two pulse outputs Din rail mounting 35mm 100A direct connection Better than Class 1 B accuracy USER MANUAL 2014 V1 0 ...

Страница 2: ...ct external CTs giving the unit a cost effective and easy operation Built in interfaces provides pulse Configuration is password protected Unit Characteristics The Unit can measure and display Line voltage and THD total harmonic distortion of all phases Line Frequency Currents Current demands and current THD of all phases Power maximum power demand and power factor Active energy imported and expor...

Страница 3: ...test and indicates the result if the test passes After a short delay the screen will display active energy measurements Measurements The buttons operate as follows 1 Selects the Voltage and Current display screens In Set up Mode this is the Left or Back button 2 Select the Frequency and Power factor display screens In Set up Mode this is the Up button 3 Select the Power display screens In Set up M...

Страница 4: ...01 China Tel 0086 573 83698881 83698882 Fax 0086 573 83698883 Web www eastron com cn 3 1 1 Phase to neutral voltages 3p4w 1 2 Phase to neutral voltages 3p3w 2 Current on each phase 3 1 Phase to neutral voltage THD 3p4w 3 2 Phase to neutral voltage THD 3p3w 4 Current THD for each phase ...

Страница 5: ...698883 Web www eastron com cn 4 Frequency and Power factor and Demand Each successive pressing of the button selects a new range 1 Frequency and Power Factor total 2 Power Factor of each phase 3 Maximum Power Demand 4 Maximum Current Demand Power Each successive pressing of the button select a new range 1 Instantaneous Active Power in kW ...

Страница 6: ... 83698881 83698882 Fax 0086 573 83698883 Web www eastron com cn 5 2 Instantaneous Reactive Power in kVAr 3 Instantaneous Volt amps in KVA 4 Total kW kVArh kVA Energy Measurements Each successive pressing of the button selects a new range 1 1 Imported active energy in kWh 1 2 Exported active energy in kWh ...

Страница 7: ...active energy in kVArh 2 2 Exported reactive energy in kVArh 3 1 Total active energy in kWh 3 2 Total reactive energy in kVArh Set up To enter set up mode pressing the button for 3 seconds until the password screen appears Setting up is password protected so you must enter the correct password default 1000 before processing If an incorrect password is entered the display will show Err ...

Страница 8: ... adjusted by the and buttons If not there maybe a further layer 4 Having selected an option from the current layer press to confirm your selection The SET indicator will appear 5 Having completed a parameter setting press to return to a higher menu level The SET indicator will be removed and you will be able to use the and buttons for further menu selection 6 On completion of all set up press repe...

Страница 9: ...ting routine The SET indicator will be removed Change password 1 Use the and to choose the change password option 2 1 Press the to enter the change password routine The new password screen will appear with the first digit flashing 2 2 Use and to set the first digit and press to confirm your selection The next digit will flash 2 3 Repeat the procedure for the remaining three digits 2 4 After settin...

Страница 10: ...minutes over which the current and power readings are integrated for maximum demand measurement The options are off 5 8 10 15 30 60 minutes 1 From the set up menu use and buttons to select the DIT option The screen will show the currently selected integration time 2 1 Press to enter the selection routine The current time interval will flash 2 2 Use and buttons to select the time required 2 3 Press...

Страница 11: ... on the meter 2 Press to enter the selection routine The current time interval will flash The options can be 0 5 10 30 60 120minutes Use and buttons to select the time required Press to confirm the set up Supply System Use this section to set the type of power supply being monitored 1 From the Set up menu use and buttons to select the System option The screen will show the currently selected power...

Страница 12: ...lse output This option allows you to configure the pulse output 1 The output can be set to provide a pulse for a defined amount of energy active or reactive Use this section to set up the pulse output Units Total kWh Total kVArh Import kWh Export kWh Import KVArh Export KVArh 1 From the Set up menu use and buttons to select the Pulse output option 2 1 Press to enter the selection routine The unit ...

Страница 13: ... kVArh 1 From the Set up menu use and buttons to select the Pulse Rate option 2 Press to enter the selection routine The current setting will flash 0 0025 0 01 0 1 1 10 100kWh kVArh per pulse Note When it s 0 0025 the LED display dft default Use and buttons to choose pulse rate On Completion of the entry procedure press to confirm the setting and press to return to the main set up menu Pulse Durat...

Страница 14: ... of the entry procedure press to confirm the setting and press to return to the main set up menu CLR The meter provides a function to reset the maximum demand value of current and power 1 From the Set up menu use and buttons to select the reset option 2 Press to enter the selection routine The MD will flash Press to confirm the setting and press to return to the main set up menu Specifications Mea...

Страница 15: ...ed active energy 0 to 999999 99 kWh Exported active energy 0 to 999999 99 kWh Imported reactive energy 0 to 999999 99 kVArh Exported reactive energy 0 to 999999 99 kVArh Total active energy 0 to 999999 99 kWh Total reactive energy 0 to 999999 99 kVArh Measured Inputs Voltage inputs through 4 way fixed connector with 2 5mm stranded wire capacity single phase two wire 1p2w three phase three wire 3p3...

Страница 16: ...h The pulse constant can be set to generate 1 pulse per dft 2 5 Wh VArh 0 01 10 Wh VArh 0 1 100 Wh VArh 1 1 kWh kVArh 10 10 kWh kVArh 100 100 kWh kVArh Pulse width 200 100 60ms Pulse output 2 is non configurable It is fixed up with active kWh The constant is 400imp kWh Reference Conditions of Influence Quantities Influence Quantities are variables that affect measurement errors to a minor degree A...

Страница 17: ...ser Manual Address No 1369 Chengnan Road Jiaxing Zhejiang 314001 China Tel 0086 573 83698881 83698882 Fax 0086 573 83698883 Web www eastron com cn 16 Dimensions Wiring diagram Three phase three wires Three phase four wires ...

Страница 18: ...EASTRON SDM630Pulse User Manual Address No 1369 Chengnan Road Jiaxing Zhejiang 314001 China Tel 0086 573 83698881 83698882 Fax 0086 573 83698883 Web www eastron com cn 17 Single phase two wires ...

Отзывы: