~ 20 ~
Chapter 6 Electrical Connection
NOTE
1.
Before installation and use of the inverter, a conductor with lug (4-6 mm
2
) must be used for
special protective earthing.
2.
Load capacity of BACK-UP output end of inverter is as follows:
(1) Inductive load (such as air conditioning, washing machine, motor, etc.): 6KVA
maximum total power of inductive load.
(2) Capacitive load (such as computer, switching power supply, etc.): 6KVA maximum total
power of capacitive load.
3.
It is required for the above load capacity to connect the system with the grid or provide the
battery with enough capacity. If the power is supplied only by PV, largest single off-grid load
is generally less than 2KW.
No.
Component
Description
1
PV string
The PV string consists of PV component string
2
Inverter
Support EAHI-3000~6000-SL series inverter
3
Battery
Select the battery according to the list of inverter and applicable
batteries