Fig. 2.4 mode selection interface
2.4.1 Constant current measurement mode
Under constant current mode, the electronic load consumes a constant current no matter
whether the input voltage is changed or not.
Operation description
:
1.Select the operation item by rotating the knob. 2. set parameters.
Press the [Enter] key to enter editing mode, select the appropriate number of digits by the direction
key, and then adjust the value by a rotary knob, [Enter] or [Esc] key to exit editing. 3. press the cor
responding [On/Off ]startup mode.
Fig. 2.4.1 mode of constant current measurement
2.4.2 Constant voltage measurement mode
In constant voltage mode, the electronic load will consume enough current to maintain the in
put voltage at the set voltage.
Operation description
:
1.Select the operation item by rotating the knob. 2. set parameters.
Press the [Enter] key to enter editing mode, select the appropriate number of digits by the direction
key, and then adjust the value by a rotary knob, [Enter] or [Esc] key to exit editing. 3. press the cor
responding [On/Off ]startup mode.
7