background image

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS – ETL LISTED 

                  2 

 
 

IMPORTANT INFORMATION

 

 

MINIMUM CLEARANCES TO COMBUSTIBLE AND NON COMBUSTIBLE CONSTRUCTION. 
 

COMBUSTIBLES:   

 

SIDES 1”     BACK 1” 

 

NON COMBUSTIBLES 

SIDES 0”     BACK 0” 

 

ADEQUATE  CLEARANCE  MUST  BE  PROVIDED  FOR  AIR  OPENINGS  INTO  THE  COMBUSTION 
CHAMBER,  FOR  SERVICING  AND  PROPER  OPERATION  (PAG  AND  PAGW  MODELS  ONLY).  A 
MINIMUM OPENING OF 24” X 24” MUST BE LOCATED ON THE BOTTOM HALF OF THE OVEN. THIS 
WILL  ALLOW  FOR  PROPER  COMBUSTION  AIR  INTO  THE  BURNER  HOUSING.    NOT  HAVING 
PROPER  COMBUSTION  AIR  WILL  CAUSE  IMPROPER  OPERATION  AND  MAY  CAUSE  DAMAGE  TO 
THE BURNER SYSTEM.  INSTALLING A SEALED ENCLOSURE AROUND THE OVEN SHELL MAY ALSO 
CAUSE  IMPROPER  OPERATION  BY  STARVING  THE  BURNER  SYSTEM  OF  COMBUSTION  AIR.    THE 
USE  OF  RETURN  AIR  SYSTEMS  OR  OTHER  VENTING  SYSTEMS  LOCATED  WITHIN  SEALED 
ENCLOSURES  WHICH  SURROUND  THE  OVEN  MAY  CAUSE  NEGATIVE  PRESSURE  AND  IN  TURN 
AFFECT THE OPERATION OF THE OVEN.  ***SEE PAGES 14 AND 15 FOR MORE INFORMATION 
FOR MORE INFORMATION PLEASE CALL:  800-840-4915 OR 818-553-1134  

 
KEEP APPLIANCE FREE AND CLEAR FROM COMBUSTIBLES. 
 
DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR TO THE APPLIANCE. 
 
ELECTRICAL DIAGRAM IS LOCATED ON THE CONTROL BOX. 
 
INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE 
NATIONAL FUEL GAS CODE ANSI Z223.1, THE NATURAL GAS INSTALLATION CODE CAN/CGA-B149.1 OR THE 
PROPANE INSTALLATION CODE CAN/CGA-149.2,  AS APPLICABLE, INCLUDING: 
 

THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE MUST BE DISCONNECTED FROM THE GAS 

SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF ½ 
PSI (3.45 Kpa). 
 

THE APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS 

INDIVIDUAL MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM 
AT THE TEST PRESSURES EQUAL TO OR LESS THAN ½ PSI (3.45 Kpa ). 
 
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL 
CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 OR THE 
CANADIAN ELECTRICAL CODE, CSA C22.1, AS APPLICABLE. 
 

ELECTRICAL AND GAS REQUIREMENTS: 

 
 

-1    120VAC – 2.5 AMP OUTLET 

 

-¾ INCH GAS OUTLET 

 

-GAS INLET PRESSURE TO OVEN:   7” W.C. FOR NATURAL, 12” W.C. FOR LP GAS 

 

-GAS REGULATING VALVE  (I.E. MAXITROL RV 53,  3-6) AND SHUTOFF VALVE BY OTHERS 

 
 

MANIFOLD GAS PRESSURE – FACTORY SETTINGS 

 

 

 

160-PAG(W)   4.5” W.C. - .170,000 BTU    

130-PAG(W)   5.0” W.C. - 140,000 BTU 

120-PAG(W)   3.5" W.C.  - 130,000 BTU           110-PAG(W)   5.0” W.C. - 110,000 BTU 
90-PAG(W)     4.0 “ W.C. - 85,000 BTU 
For LP Gas see page 17 

Содержание 60-PAGW

Страница 1: ...MINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SER...

Страница 2: ...CE ELECTRICAL DIAGRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION...

Страница 3: ...ALL INSTRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNE...

Страница 4: ...OPPOSITE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLO...

Страница 5: ...rewood container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper...

Страница 6: ...perienced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection a...

Страница 7: ...VE BURNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER A...

Страница 8: ...L COME BACK ON TEMPERATURE READOUT CONTROLS 4 BLACK DIAL KNOB ROTATE CLOCKWISE TO RAISE OR COUNTER CLOCKWISE TO LOWER SET TEMPERATURE 5 RED BUTTON USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPE...

Страница 9: ...S ON OVEN INTERIOR WILL TURN BLACK IF DOOR IS CLOSED WHILE BURNER IS ON A BACK FLASH CAN ALSO OCCUR AFTER TWO HOURS TURN OVEN OFF AND CLOSE OVEN DOOR DO NOT USE ANY CLEANING AGENTS IN THE OVEN SHUTTIN...

Страница 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS ETL LISTED 10 GAS BURNER CONTROLS...

Страница 11: ...the oven may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended...

Страница 12: ...LATION INSTRUCTIONS ETL LISTED 12 GAS BURNER WOOD All wood fired in a gas wood combination oven should be located on the opposite side of the gas burner Take caution to avoid ashes from entering the g...

Страница 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS ETL LISTED 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG...

Страница 14: ...4 x24 opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed f...

Страница 15: ...e pressure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable...

Страница 16: ...TO INCREASE REMOVE OVEN DOOR OVEN DOOR SHOULD NOT BE CLOSED WHEN OVEN IS FIRED OVEN DOOR CAN BE POSITIONED AT A 45 DEGREE ANGLE TO ALLOW FOR MORE RAPID HEAT UP WITH A 2 SIDED OVEN YOU CAN HAVE ONE DO...

Страница 17: ...0 PAGW 4 W C 85 000 btu 110 PAGW 5 W C 110 000 btu 120 PAGW 3 5 W C 130 000 btu 130 PAGW 5 W C 140 000 btu 160 PAGW 4 5 W C 170 000 btu Add 0 5 W C for ovens with rear burner LP Gas Manifold pressure...