e z L C D -‐ 4 0 5
|
63
Rev.
© 2016 Earth Computers Tech. Inc.
1.7.6 BUTTONS_ALL_UP
Description:
Changes the state of all defined touch buttons to Button Up
Code:
B3
hex,
179
dec
7
6
5
4
3
2
1
0
Byte 0: Command
Note:
The button will be automatically redrawn, if the icon for the Button Up has been defined by the
BUTTON_DEF
command.
See Also:
BUTTON_DEF
,
BUTTON_STATE
,
BUTTONS_DELETE_ALL
,
TOUCH_PROTOCOL
Important:
Before using this command, please read the following chapters:
·∙
Touch Screen
·∙
ezButton
·∙
cuButton
Example:
Example:
The following sequence will change the state of all Buttons to Up.
BUTTONS_ALL_UP B3
hex
(Command)