EarthCore Isokern Maximus Linear 82L120ST Скачать руководство пользователя страница 67

Earthcore Industries  

02/2021 

 

 Isokern Maximus Linear Series See-Thru Gas Fireplace 

67 

 

Glass Media Options 

 

Component

 

Part#

 

Description

 

 

 

 

 

 

RFG-10-PB

 

 

 

 

1/2” REFLECTIVE POSEIDON 

BLUE FIRE GLASS (10 LB JAR)

 

 

 

 

 

 

RFG-10-TC

 

 

 

 

1/2” REFLECTIVE TERRA 

COPPER FIRE GLASS (10 LB 

JAR)

 

 

 

 

 

 

RFG-10-VB

 

 

 

 

1/2” REFLECTIVE VESPER 

BLACK FIRE GLASS (10 LB 

JAR)

 

 

 

 

 

 

RFG-10-KD

 

 

 

 

1/2” REFLECTIVE KRYSTALLO 

DIAMOND FIRE GLASS (10 LB JAR)

 

 

 

 

 

 

RFG-10-AD

 

 

 

 

1/2” REFLECTIVE AMBER 

DIAMOND FIRE GLASS (10 LB 

JAR)

 

 

Glass Media will be included with the Isoflames Linear Burner for each Maximus Linear Unit.  A color selection will 

need to be chosen when ordering your fireplace unit. The following designated amount will be included for each 

size.

 

 

 

82L48 - 3 (10lb)  Jars

 

 

82L72 - 5 (10lb)  Jars

 

 

82L96 - 7 (10lb)  Jars

 

 

82L120 - 9 (10lb) Jars

 

Содержание Isokern Maximus Linear 82L120ST

Страница 1: ...urer s listing and explicit installation and operation instructions Be Sure to Read Entire Manual Before Beginning Construction Contents of this manual may change without prior notification PFS Report...

Страница 2: ...ation 32 Enervex MFD General Information 33 Enervex RS Chimney Fan General Information 34 Enervex MFD Vertical Termination Installation 35 Enervex RS Chimney Fan Installation 36 Enervex MFD Horizontal...

Страница 3: ...any component part not approved by Earthcore Industries in combination with this appliance 3 Installation or operation in a manner other than instructed in this manual 4 Burning of anything solid fue...

Страница 4: ...fe operation of this fireplace WARNING This unit is not for use with solid fuel 1 Always check local building codes governing fireplaces and fireplace installations The Isokern Maximus Linear Series i...

Страница 5: ...any gas control which has been under water 19 The Isokern Maximus Linear Series is not intended to heat an entire home or to be used as a primary heat source 20 Children and adults should be alerted t...

Страница 6: ...Earthcore Industries Isokern Maximus Linear Series See Thru Gas Fireplace 02 2021 6 Isokern Maximus Linear Series 48 See Thru 82L48ST...

Страница 7: ...Thru Components 82L48ST Component Part Description 13 Smoke Dome 46 48 Qty 2 34 Smoke Dome Side Wall Qty 2 70 Damper Beam 46 48 Qty 2 81 Top Plate 46 48 Qty 1 Component Part Description M65A Sidewall...

Страница 8: ...mus Linear Series See Thru Gas Fireplace 02 2021 8 Isokern Maximus Linear Series 72 See Thru 82L72ST Steel angle 6 x 6 x 1 2 cut to span firebox opening This item is not included in the components and...

Страница 9: ...uded in the components and can be sourced locally Component Part Description 16 Smoke Dome 60 72 Qty 2 18 Smoke Dome 72 Qty 2 34 Smoke Dome Side Wall Qty 2 69 Damper Beam 42 Qty 2 77A Top Plate 36 42...

Страница 10: ...Maximus Linear Series See Thru Gas Fireplace 02 2021 10 Isokern Maximus Linear Series 96 See Thru 82L96ST Steel angle 6 x 6 x 1 2 cut to span firebox opening This item is not included in the component...

Страница 11: ...ocally Component Part Description 16 Smoke Dome 60 72 Qty 2 17 Smoke Dome 60 Qty 2 34 Smoke Dome Side Wall Qty 2 68 Damper Beam 36 Qty 2 77A Top Plate 36 42 Qty 1 113 Smoke Dome 96 Qty 2 122 Top Plate...

Страница 12: ...Series See Thru Gas Fireplace 02 2021 12 Isokern Maximus Linear Series 120 See Thru 82L120ST Steel angle 6 x 6 x 1 2 cut to span firebox opening This item is not included in the components and can be...

Страница 13: ...ocally Component Part Description 16 Smoke Dome 60 72 Qty 4 34 Smoke Dome Side Wall Qty 2 69 Damper Beam 42 Qty 2 70 Damper Beam 46 48 Qty 2 74 Damper Beam 60 Qty 2 77A Top Plate 36 42 Qty 1 116 Smoke...

Страница 14: ...stalling on a combustible floor system the area in front of the fireplace must be covered with a non combustible hearth extension that is set tight against the fireplace front The hearth extension sha...

Страница 15: ...bs includes steel angle but no burner flue accessories d Maximus Linear See Thru 120 2 756 lbs includes steel angle but no burner flue accessories 2 Approximate weight of log set 100 lbs 3 Fire brick...

Страница 16: ...aised hearth height When calculating raised hearth height be sure to allow for the 3 thick base plate plus the 2 1 2 thick fire brick floor in addition to the height of the platform The platform shall...

Страница 17: ...rthcore Adhesive should squeeze out along the face of the entire joint as a sign of complete and proper sealing of the joint On broader contact surfaces it is advisable to apply several additional bea...

Страница 18: ...joint as the firebox assembly progresses 1 Apply Earthcore Adhesive to the joints between each baseplate part and ensure to set each base plate in a full bed of Earthcore Adhesive on a level support s...

Страница 19: ...areas on the base plate 3 Continue assembly of the consecutive courses of the firebox side walls Apply Earthcore Adhesive to the top of each layer of side wall components before setting the next cours...

Страница 20: ...e iron These recesses shall begin at the front of the top sidewall components and extend 5 towards the center of the firebox These notches ensure that the angle iron is level and flush with the top of...

Страница 21: ...back lintel Each of the damper end blocks are designed for a specific side of the unit When properly set the vertical face of each damper end block will be flush with the outside face of the firebox s...

Страница 22: ...g sidewall components The sloping side walls will be placed in between the front and rear smoke dome components at the ends of the firebox and are designed to rest in their notched ends Once assembled...

Страница 23: ...re Industries 02 2021 Isokern Maximus Linear Series See Thru Gas Fireplace 23 Assembled Maximus Linear See Thru Units Assembled 48 Maximus Linear See Thru 82L48ST Assembled 72 Maximus Linear See Thru...

Страница 24: ...e Industries Isokern Maximus Linear Series See Thru Gas Fireplace 02 2021 24 Assembled Maximus Linear See Thru Units Assembled 96 Maximus Linear See Thru 82L96ST Assembled 120 Maximus Linear See Thru...

Страница 25: ...at the air kit duct be routed in the most direct path to the outside wall of the building Air kits are typically supplied with 10 duct sections It is recommended not to exceed twenty feet 20 of four i...

Страница 26: ...ey life Interior chimneys shall be enclosed where they extend through closets storage areas occupied spaces or anywhere the surface of the chimney could be contacted by persons or combustible material...

Страница 27: ...et angle of 90 Contact Earthcore representative for total distances exceeding the table minimums maximums Selecting Horizontal or Vertical Venting System With the appliance secured determine vent rout...

Страница 28: ...en center anchor plate over the Isowool blanket Figure 18 3 Secure the Anchor Plate with four 4 masonry anchors 4 Starting at the anchor plate attach the first section of B Vent Pipe The B Vent sectio...

Страница 29: ...to be centered in the firestop s opening When installed check to make sure the one inch 25 4 mm clearance to combustible has been maintained IMPORTANT If the area above the penetration is an attic the...

Страница 30: ...s NOTE A B Vent support plate MSP is required if vertical height exceeds 30 feet Maximum of 30 feet between supports 9 The vertical vent system will be terminated with a mechanical draft system Instal...

Страница 31: ...e up to the location of termination 12 If the installation must pass through an attic floor or ceiling the B vent Firestop shall be utilized To pass the pipe through the floor ceiling begin by cutting...

Страница 32: ...om any authorized ENERVEX representative Accessories fans and variable frequency drives are not covered by this manual Please refer to these component s individual manuals IMPORTANT TO REDUCE THE RISK...

Страница 33: ...ve for fireplace operation The actuator has two end switches to prove damper position open or closed and is equipped with the Enerdrive fail safe system to open the damper in the event of an electrica...

Страница 34: ...quired by the authority having jurisdiction the installation must also conform to the Standard for Draft Equipment and The National Fuel Gas Code ANSI Z223 1 NFPA 54 All electrical wiring must be in a...

Страница 35: ...silicone Install a weatherproof cable connector on the side of the actuator cover to prevent water ingress to the actuator 3 Use 6 of the included sheet metal screws to secure the actuator cover to t...

Страница 36: ...d Fan Installation Vertical Termination 5 Measure the inside diameter of the flue and cut a corresponding hole in the center of the fiber mat If the flue is so big that the throat in the adapter has b...

Страница 37: ...tor cover to prevent water ingress to the actuator 3 Use 6 of the included sheet metal screws to secure the actuator cover to the MFD Once secure apply a bead of silicone around the seams of the cover...

Страница 38: ...to the structure that is within 10 ft 3 m of the termination point Exception This requirement shall not apply to the separation distance between the circulating air inlet and the vent discharge of a...

Страница 39: ...Earthcore Industries 02 2021 Isokern Maximus Linear Series See Thru Gas Fireplace 39 Complete Electrical Schematic FIGURE 35...

Страница 40: ...he roof or in a horizontal mount on an outside wall Junction capacitor box will be mounted near the fan mount Fan circuit disconnect de energizes the fan circuit for the purpose of servicing recommend...

Страница 41: ...ring must be in compliance with the local codes or in their absence with the National Electric Code NFPA 70 latest edition If an external electrical source is utilized system must be electrically grou...

Страница 42: ...itch PDS must be used with the ADC100 control as a system safety device The PDS monitors the pressure inside the stack and signals the control to shut down the appliance if insufficient draft exists A...

Страница 43: ...installed close to the fan inlet See Figure 43 7 To produce an accurate pressure reading the probe should be installed flush with the inner wall of the chimney or stack If double walled stack is used...

Страница 44: ...rol system Terminal Description Terminal Description 1 Line Power L1 11 Proven Draft Switch NO white 2 Line Neutral 12 Proven Draft Switch NC gray 3 Ground 13 Proven Draft Switch C purple 4 Fan Power...

Страница 45: ...lied Approximately 35 to 40 lbs of prepared mortar will lay up one hundred 9 x 4 x 2 straights IMPORTANT DO NOT add additives such as fire clay sand cement or other accelerators These instructions may...

Страница 46: ...sion 2 Repeat Step 1 for the opposite side of See Thru firebox 3 Starting at the front edge of the unit s sidewall apply split firebrick to the side wall of the unit Ensure approximately gap is kept b...

Страница 47: ...etting the noncombustible facing material onto the drywall that spans across the top of the firebox opening there will be a gap between the back of the noncombustible finish material and the rough fro...

Страница 48: ...that create the room wall finish All combustible trim projecting less than one and one half inch 1 1 2 from this plane must be kept a minimum of eight inches 8 from the sides top of the firebox openin...

Страница 49: ...of 1 2 psi 3 5 kPa The appliance must be isolated from the gas piping system by closing its equipment shutoff valve during any pressure testing of the supply piping system at test pressures equal to o...

Страница 50: ...sort may void manufacturer s warranty listings and approvals 25 The ISOFLAMES Linear Burner system is not intended to heat an entire home or to be used as a primary heat source 26 Children and adults...

Страница 51: ...ven though no odor exists Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble flu symptoms including headaches dizziness or nausea If you have these signs the fireplace may not...

Страница 52: ...er Assembly propane ISF E 36 60 72 96N ISF E 36 60 72 96P 1 1 2 Pilot Assembly natural gas Pilot Assembly propane ISF E PAN ISF E PAP 1 1 3 Gas Valve natural gas Gas Valve propane ISF E GVN ISF E GVP...

Страница 53: ...ecifications Burner Specifications Burner Model Minimum Fireplace Dimension in BTU Depth Height Width Nat Gas L P Gas Front Rear High Low High Low ISF36LB 17 5 16 48 37 54K 38K 48K 36K ISF60LB 17 5 16...

Страница 54: ...off gas and electricity before starting installation or service 5 Make sure gas piping is pressure tested before control is connected High pressure can damage the control causing a hazardous condition...

Страница 55: ...kPa The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 If not installed and maint...

Страница 56: ...ortion of this manual pgs 45 46 3 The burner cavity must have a height of 2 1 2 a depth of 9 1 4 and the length shall extend the entire width of firebox Table 5 4 The 48 and 72 Maximus Linear See Thru...

Страница 57: ...ector to the gas inlet flared fitting on the burner assembly 7 Connect the other end of 12 flex connector to the gas supply 8 Avoid creating kinks in the flex connector 9 Make sure all connections are...

Страница 58: ...place 02 2021 58 36 Burner Connection ISF36LB For Isokern Maximus Linear 82L48ST 60 Burner Connection ISF60LB For Isokern Maximus Linear 82L72ST ISF36LB Box No Part No Qty 4 E 18BP4 1 8 E 12BP1 1 ISF6...

Страница 59: ...2021 Isokern Maximus Linear Series See Thru Gas Fireplace 59 72 Burner Connection ISF72LB For Isokern Maximus Linear 82L96ST ISF72LB Box No Part No Qty 4 E 18BP4 1 5 E 18BP5 1 9 E 12BP2 1 10 E 12BP3 1...

Страница 60: ...ear Series See Thru Gas Fireplace 02 2021 60 96 Burner Connection ISF96LB For Isokern Maximus Linear 82L120ST ISF96LB Box No Part No Qty 2 E 18BP2 1 3 E 18BP3 1 9 E 12BP2 1 10 E 12BP3 1 11 E 12BP4 1 1...

Страница 61: ...than air and will settle on the floor WHAT TO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supp...

Страница 62: ...the battery bay in the transmitter Correctly align polarity 2 Insert the four 4 provided AA batteries into the wall switch battery bay behind the wall switch plate Correctly align polarity 3 On the w...

Страница 63: ...appliance pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arro...

Страница 64: ...veral cycles to purge out all the air in pilot tube 7 Once the pilot is ignited the main burner valve will turn on within 7 seconds 8 The burner should ignite and the flames should travel along the le...

Страница 65: ...in pilot gas line It may take a few minutes to purge out all the air from the pilot gas tube to ignite No gas Verify pilot gas tube is threaded sufficiently to gas valve Verify all gas connections goi...

Страница 66: ...rove go into alarm for 30 seconds followed by a full retry Flashes 3 If PDS loses proof for 15 seconds after initial PDS prove AUX OUT de energize stay in alarm until PDS prove returns and AUX OUT wil...

Страница 67: ...LECTIVE VESPER BLACK FIRE GLASS 10 LB JAR RFG 10 KD 1 2 REFLECTIVE KRYSTALLO DIAMOND FIRE GLASS 10 LB JAR RFG 10 AD 1 2 REFLECTIVE AMBER DIAMOND FIRE GLASS 10 LB JAR Glass Media will be included with...

Страница 68: ...Earthcore Industries Isokern Maximus Linear Series See Thru Gas Fireplace 02 2021 68...

Страница 69: ...s warranty the party to whom this warranty is extended shall notify ISOKERN 6899 Phillips Industrial Blvd Jacksonville Florida 32256 in writing by registered mail within thirty 30 days following the d...

Отзывы: