Enervex ADC 100 Installation
Connection Diagram
Overall Connection Diagram Notes
•
Power supply shall be from building source power on a dedicated circuit
•
RS fan wiring shall be dedicated for the fan; branching of the circuit will cause erratic fan behavior
•
RS Fan and Mechanical Fireplace Damper may be installed in a vertical mount above the roof or in a horizontal mount on
an outside wall.
•
Junction / capacitor box will be mounted near the fan mount
•
Fan circuit disconnect de-energizes the fan circuit for the purpose of servicing - recommended installed by the
manufacturer – must meet local code requirements; not supplied
•
Fan speed control switch is installed for the purpose of fan speed initial set up; should be mounted in a location that is not
accessible to the general public
•
MFD wiring details – page 41
•
RS fan circuit wiring details – page 41
•
Proved Draft Switch, PDS wiring details – page 42
•
ADC100 wiring details - page 48
•
Fireplace wiring details – page
55
FIGURE 38