Eagle Nebula Скачать руководство пользователя страница 1

USER MANUAL

Weighing Indicators

Version - 1.00

Manual Rev No - 002

Nebula & Splash

Содержание Nebula

Страница 1: ...USER MANUAL Weighing Indicators Version 1 00 Manual Rev No 002 Nebula Splash...

Страница 2: ......

Страница 3: ...lay and Key Descriptions 4 1 5 1 Display LED 4 1 5 2 Keypad LED 5 1 5 3 Display LCD 6 1 5 4 Keypad LCD 7 1 5 5 Keys and Key Press Description 8 1 5 6 Two Keys Pressing Together Functions 8 2 User Sett...

Страница 4: ...3 System Setting SySt 20 3 1 Date Format dtF 20 3 2 Set Date dtE 21 3 3 Time Format tIF 21 3 4 Set Time tIE 21 3 5 Serial Number SrnO 22 3 5 1 Serial Number Prefix SrPF 22 3 5 2 Serial Number Interva...

Страница 5: ...r Stable oSt 28 4 1 6 5 Only Once After Stable oSto 28 4 1 6 6 Command Cd 29 4 1 7 Starting Character StCH 29 4 1 8 String Direction di 30 4 1 9 Decimal Point Transmit dp 31 4 1 10 Transmit Sign SG 31...

Страница 6: ...ttL 36 5 Factory Settings 37 5 1 Scale Setting SCSt 37 5 1 1 5 1 4 Intentionally kept blank 5 1 5 Range rng 37 5 1 5 1 SR Single Range 37 5 1 5 2 DR Dual Range 38 5 1 5 3 TR Triple Range 38 5 1 7 Cap...

Страница 7: ...6 3 Check Weighing Check Counting 41 6 4 Accumulation 43...

Страница 8: ...nish quality reduce profits and increase liability Timely service from EAGLE will ensure accuracy and optimize uptime and equipment life a Installation Configuration Integration and Training Our servi...

Страница 9: ...EAGLE It may not be copied in whole or in part without the express written consent of EAGLE EAGLE reserves the right to make refinements or changes to theproduct or manual without notice COPYRIGHT EA...

Страница 10: ...justments that must be made with power on Failing to observe these precautions can result in bodily harm Warning For continued protection against shock hazard connect to properly grounded outlet only...

Страница 11: ...requirements Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the...

Страница 12: ...9 Weighing Check weighing Piece Counting Check Counting Accumulation Peak Hold modes 10 Provision to connect with portable thermal printer 11 Optional Bluetooth and RTC Card 1 2 Specifications Display...

Страница 13: ...prepare a special power line and grounding 5 V 2 4 A power supply adapter is used for the power supply Power supply pin C type USB is located at the rear side of the indicator in the ABS indicator an...

Страница 14: ...tion as per below 1 Ex 2 Ex 3 Sig 4 Sig 5 Shield Load cell Connector SS ABS Variant 4 wire LC connection 1 4 Physical Dimensions Please refer below dimension of Nebula SS Indicator and ABS Indicator N...

Страница 15: ...or comes with two variant displays LED and LCD 1 The following are the indications in the LED display Gross Indicates the displayed weight is gross weight Net Indicates the displayed weight is net wei...

Страница 16: ...Indicates the peak hold function is enabled It is used in check weighing or check counting function If this Yellow LED glows then the weight or count is under range It is used in check weighing or ch...

Страница 17: ...gross weight NW Indicates the displayed weight is net weight Indicates the scale counts are in zero condition Indicates the weight value is unstable Units g kg lb L t units are available on the right...

Страница 18: ...D glows then the weight or count is under range It is used in check weighing or check counting function If this Green LED glows then the weight or count is in OK range It is used in check weighing or...

Страница 19: ...t come first serve basis 5 Func Esc N G Bluetooth name Note To come out press ESC key Keys Func Esc Zero Tare N G M MR Short press from home screen To enter into counting mode To make the display zero...

Страница 20: ...fter pressing these two keys together display will show the last selected Location and increment key decrement key is used to scroll from W1 to W9 C1 to C9 and also to NIL When NIL is selected no chec...

Страница 21: ...t value is 3 This is used to vary the display speed 1 is the fastest and 5 for slowest Once the speed is chosen between 1 to 5 press ENTER button to select and after selection the display will come to...

Страница 22: ...chosen between Y or n press ENTER button to select and after selection the display will come to the previous menu Note It is available only in LCD Variants 2 4 Display Backlight colour bLCL When ENTE...

Страница 23: ...vironment conditions For example if we enter 05 here and the scale least count division is 2 g then 2 g x 5 10 g so up to 10 g display will track the values to zero 2 6 Zero Lock ZLOC When ENTER key i...

Страница 24: ...is more than 20 of the full scale then the display will show Err20 If the display shows Err20 then the scale should be checked and remove the extra weights placed on the platform and ensure the platfo...

Страница 25: ...will off and LED will show zero in dim 2 10 Auto Tare AtrE When ENTER key is pressed from AtrE n the display will start flashing n Default value is n y Auto Tare ON n Auto Tare OFF When the scale is i...

Страница 26: ...rement Tare key for decrement and N G for shift 2 12 Stability Stb When ENTER key is pressed from Stb 01 the display will start flashing last digit 01 Default value is 01 Stability is the time require...

Страница 27: ...e done using M MR key tH Thresh Hold value It is related to the accumulation auto mode You can enter a threshold value here when the weight is above this threshold value the auto accumulation will hap...

Страница 28: ...Default value is 000 000 Use Zero key for the increment and Tare key for the decrement and N G key for the shift Once the value is entered as per requirement press ENTER button to select and after se...

Страница 29: ...000 Default value is 000 000 Use Zero key for the increment and Tare key for the decrement and N G key for the shift Check Weighing will happen if the current display value is greater than the thresh...

Страница 30: ...LL Use Zero key for the increment and Tare key for the decrement to scroll between LL HL bZ and tH When ENTER key is pressed from C1 LL the display will show the 000000 Default pieces are 000000 Use Z...

Страница 31: ...tart ringing Once the In or out is chosen as per requirement press ENTER button to select and after selection the display will go to the previous menu When ENTER key is pressed from C1 tH the display...

Страница 32: ...Use Zero key for the increment and Tare key for the decrement and N G key for the shift and enter the password 123456 and then press ENTER button to enter into System setting menu 3 1 Date Format dtF...

Страница 33: ...will go to the previous menu 1 You can set the date when the optional Add on card with RTC is used 3 3 Time Format tIF When ENTER key is pressed from tIF 12 the display will start the flashing 12 Defa...

Страница 34: ...the time when the optional Add on card with RTC is used 3 5 Serial Number SrnO In the Serial Number 3 sub menu are available Serial Number Prefix SrPF Serial Number Interval SrLn Serial Number Reset...

Страница 35: ...the multiplies of 2 ie 2 4 6 Once the interval is chosen between 1 to 9 press ENTER button to select and after selection the display will go to the previous menu 3 5 3 Serial Number Reset rSt When we...

Страница 36: ...or functions Except calibration settings When we press enter key from FrSt the display will show FrSt y FrSt y Do the factory reset FrSt n Do not do the factory reset When we press enter key from FrS...

Страница 37: ...conversions from above list the display will show Yes or No option y or n User can set as per their requirement Use Zero key up arrow and Tare key down arrow to toggle between Yes and No N G Tare Thi...

Страница 38: ...s selected press ENTER button to select and after selection the display will go to the previous menu and show the selected baud rate Press Tare button to go to the next parameter 4 1 2 Data Bits db Wh...

Страница 39: ...ll start flashing n Default value is n The following are the parity available None n Even E Odd o Select as per requirement and press ENTER button to select and after selection the display will show t...

Страница 40: ...etween OFF Con Prt OSt OStO Cd 4 1 6 1 OFF If OFF is selected the RS232 data transmission will be disabled 4 1 6 2 Continuous transmission Con This will transmit the weight continuous to the receiving...

Страница 41: ...A Default value is A If CD is selected in transmission mode then we have to enter any one character here On receiving this character weight will be transmitted only once from the indicator Use Zero ke...

Страница 42: ...pressed from di F the display will start flashing f Default value is f Using the String direction we can set the RS232 string direction either in forward or in reverse F Forward To transmit weight on...

Страница 43: ...ay is 8 532 considering F Forward in previous settings then in RS232 the weight will be transmitted as 8532 Press ENTER button to select and after selection the display will show the dp Y or dp n as p...

Страница 44: ...fault value is Y This setting decides whether the leading zero before the weight value should be transmitted in the RS232 string or not Use Zero Tare Key to choose Y or N and press ENTER key Y Yes To...

Страница 45: ...t transmit leading zero Press ENTER button to select and after selection the display selected value Press Tare key to go to next parameter 4 1 13 Line Feed LF When ENTER key is pressed from LF Y the d...

Страница 46: ...tion the display will selected value Press Esc button to go the main sub menu 4 2 Bluetooth bLE When ENTER key is pressed from bLE the display will show FUnC Please note bluetooth is an optional featu...

Страница 47: ...as the name for the bluetooth to identify We can use any alphabet or numbers to set the device bluetooth name Use Zero and Tare key for increment and decrement of the values and use N G key for left...

Страница 48: ...same like RS232 settings Refer section no 4 1 9 4 2 9 Transmit Sign SG It is same like RS232 settings Refer section no 4 1 10 4 2 10 Leading Zero LZ It is same like RS232 settings Refer section no 4 1...

Страница 49: ...5 1 3 Year yr This is for engineering purpose Not applicable for the user 5 1 4 Production Date Pdt This is for engineering purpose Not applicable for the user 5 1 5 Range rng In this indicator three...

Страница 50: ...the division and above 20 to 30 kg we can use the scale with 5 g as the division Once the range is chosen press ENTER button to select and after selection the display will go to the previous menu 5 1...

Страница 51: ...After setting the range capacity division decimal point and unit we have press the Tare Key then the display shows FCAL Factory Calibration Then follow the following process 1 The display shows ZCAL z...

Страница 52: ...ation We have to make sure there is no weight in the platform and then press the M MR Key enter Now the display will show AD counts 4 Once again press the M MR Key The display will show LOAD and we ha...

Страница 53: ...g odd pieces for Ex We want to sample 150 pieces for that we need to use S cnt in this function we can add 4 digit sampling value When we enter from the S cnt display will show 0000 here we need to ad...

Страница 54: ...r the sampling Once the Pieces for sampling is kept on the scale press Func ESC key The display will be Show S 0 S cnt S 10 S 20 S 50 S 100 S 200 S 500 To Scroll between the S 0 to S 500 use Func Key...

Страница 55: ...00 500kg then displays colour change into Green and ok led will be on and buzzer will be start ringing When weight is above the 001 000kg then display colour will be change into red and high indicatio...

Страница 56: ...mulated weight press Func M MR the display will show the accumulated weight Press Func key to go weighing mode To view to accumulated time press Func Tare the display will show the accumulated time Pr...

Отзывы: