background image

The device is comprised of two sub-assemblies: a male bullet catch and a female

receiver with a locking plate.

1. Align the units so that the bullet catch and receivers line up.

2. Pull the lever and push the two units together so that the bullet catch 

is pushed all the way into the receiver.

3. Release the lever and the two units are now securely docked together.

4. To release the two units, pull the lever and slowly pull the two units

apart. Release the lever and now your units are separate. 

DOCKING DEVICE

OPERATIONS MANUAL & INSTRUCTIONS

Director’s Choice

®

Cold Food Unit with 

Refrigerated Base

Models #DCS4-CFRB & DCS5-CFRB

EG10077      Revised 12/07

PART #366615

Eagle Foodservice Equipment, Eagle MHC, SpecFAB, and Retail Display are divisions of Eagle Group. ©2007 by the Eagle Group

• 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S.A. • www.eaglegrp.com 

• Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100 

• Fax: 302/653-2065

Retain this manual
for future reference.

bullet catch

receiver

lever

CAUTION

INSPECT CONTENTS IMMEDIATELY AND FILE CLAIM WITH DELIVERING 

CARRIER FOR ANY DAMAGE.

SAVE YOUR BOX AND ALL PACKING MATERIALS.

YOU ARE RESPONSIBLE FOR DAMAGE TO YOUR UNIT IF RETURNED 

IMPROPERLY PACKED.

OPERATION FOR MECHANICAL COLD PANS

All units come equipped with 110V, 60 cycle, single phase refrigeration units. The unit is ready to operate as soon as it is plugged in.

However, we do recommend that the unit be plugged in and allowed to cool for approximately 30 minutes before using. The unit has

been pretested and set for proper operation. The thermostat has been set from 35˚ to 40˚F. 

1. Connect unit to proper power source (120V AC, 60Hz, 15A, single-phase). 

2. Turn unit on. 

3. With ambient room temperature of 75˚F, allow 60 - 90 minutes before loading with food. This allows interior to cool down to the

correct storage temperature. The thermostat is preset at the factory to maintain an average interior temperature of 38˚F. 

MAINTENANCE FOR MECHANICAL COLD PANS

Proper cleaning of the unit is is required. When rubbing or scouring, always move gently in the direction of the polish lines (grains). 

A Scotch-Brite™ general purpose pad may be used. DO NOT USE STEEL WOOL. Clean condenser coil regularly. Defrost unit whenever

1/2˝ of ice forms on inner liner. Keep well ventilated. 

MAINTENANCE FOR LAMINATES

Laminate surfaces should be cleaned with warm water and mild soaps. Non-abrasive cleaners may also be used. Cleaning products

containing bleaching agents should not be used, large quantities of these agents or extended periods of time can cause discoloration. 

CAUTION:

1. This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold 

for consumer use in and around the home nor for use directly by the general public in food service locations.

2. Do not immerse unit in water.

3. All repairs should be done by an authorized service center.

4. Unit should be turned off when not in use. It is recommended that unit be disconnected from power supply by removing plug from

receptacle or shutting off power disconnect supply to the unit. 