background image

4

After taping the wire ends individually, wrap the entire connection

with electrical tape as shown. This will help protect from moisture and

prevent the wires from breaking contact.

Wiring Diagram "B"

If your VHF radio or other device requires true RS-232, you will need to
remove the diode and resistor built into the end of the Cuda 240i data cable.

You will notice near the end of the cable a segment protected with black
heat-shrink. To connect the Cuda 240i to a true RS-232 radio, first
remove the Uniden adapter segment of the cable as shown in the
following figures.

     

For Wiring Diagram B installations, remove the Uniden adapter

segment at the end of your data cable as shown at left. Snip off the end

of the cable protected by the black heat-shrink. At right, we have used

clear heat-shrink for clarity, so you can see the diode and resistor

protected within. Remove this portion of the cable.

Содержание CUDA 240I S

Страница 1: ...ed with the Digital Selective Calling DSC distress call feature To send NMEA 0183 data the Cuda 240i has one NMEA 0183 version 2 0 communication port The com port can be used to send NMEA formatted data such as your current position The provided Cuda 240i data cable plugs into the accessory socket on the right side of the back of your unit s case The data cable ends in two wires that connect to yo...

Страница 2: ...st other connection types TTL NMEA and NMEA differential will require Wiring Diagram A Recommended Tools and supplies Recommended tools for this job include wire pliers or wire stripper and a wire cutter Required supplies for this job include two gray 18 gauge or blue 16 gauge wire nuts and electrical tape Supplies are not included Wiring Diagram A Begin by stripping the wire ends of the device yo...

Страница 3: ...e Wiring Diagram B instructions at the end of page 3 Com port wiring to transmit NMEA information to a Uniden or similar VHF radio or other device Twist the appropriate wires together making sure that the exposed ends make good contact Secure the wire ends with wire nuts then wrap each wire nut securely with electrical tape to protect against moisture as shown in the figure on the right Ground Shi...

Страница 4: ...ble You will notice near the end of the cable a segment protected with black heat shrink To connect the Cuda 240i to a true RS 232 radio first remove the Uniden adapter segment of the cable as shown in the following figures For Wiring Diagram B installations remove the Uniden adapter segment at the end of your data cable as shown at left Snip off the end of the cable protected by the black heat sh...

Страница 5: ...other device If you re using a true RS 232 radio or other device connect its Receive wire to the Cuda 240i data cable s yellow wire and its ground or Receive wire to the Cuda 240i data cable s bare shield wire Com port wiring to transmit NMEA information to another standard NMEA compatible device When the data cable is connected to your VHF radio all you have to do is plug it into the sonar GPS un...

Страница 6: ... in the back of the unit s manual To set Com Port Configuration 1 Press MENU MENU to SYSTEM SETUP ENT 2 Press to COM PORT ENT A menu appears with a drop down Baud Rate selection box highlighted The menu also contains an on off checkbox to activate NMEA Output and a button that activates the Configure NMEA command described in the following section To set Baud Rate With the Baud Rate box selected t...

Страница 7: ...ing has all NMEA sentences turned on Press to CONFIGURE NMEA ENT NMEA Sentences selection menu A menu appears showing the prefixes of the available NMEA sentences A check mark next to a prefix means the prefix is in use Use to select a prefix then press ENT to turn off the prefix Press ENT again to check the box and turn a prefix on NOTE The names of the NMEA sentences are abbreviated in this menu...

Страница 8: ...ture in marine radios is relatively new technology The U S Coast Guard for example implemented its first DSC capable systems in Atlantic City N J and Chincoteague VA in September 2003 However the entire U S DSC rescue system won t be operational until Sept 30 2006 As more marine electronics manufacturers enter this growing market other connectivity issues with your unit may appear You can check fo...

Отзывы:

Похожие инструкции для CUDA 240I S