CHECKING THE SYNCHRONISATION BOARD PILOT (OCXO)
AVAILABILITY
• No mission capable
FREQUENCY
• Every five years
OPERATOR(S)
• 1 operator
TIME REQUIRED
• 30 minutes
TOOL(S)
• 1 standard tool box
• 1 power meter + power QMA male 50
Ω
adaptor
• 1 electronic c 1 measuring cable fitted with a QMA male 50
Ω
adaptor
PRODUCT(S) / CONSUMABLE(S)
• Not applicable
PRELIMINARY OPERATION(S)
• Check that the electronic counter satisfies all the required characteristics at the time the
measurement is taken (see Section 4.3.4.1)
.
• Remove the upper cover (Plate 6.I, item 1).