Description
2-19
1
2
3
4
5
2.3
SPECIFICATIONS
2.3.1
Physical specifications
Rack dimensions:
• Width: 445 mm without bracket, 482.6 mm with mounting brackets
• Height: 133 mm (3U)
• Depth: 400 mm
Rack weight:
• Equipped rack: < 20 kg
Length of cables:
• Antenna cable: 7.5 m
• Mains power supply cable: 2.5 m
• DC power supply cable: not supplied
- < 2.5 m
- wire section: 4 mm
2
• TPS cable: 1,5 m
2.3.2
Electrical specifications
Power supply:
(see tolerances in Section 2.3.4.1)
• mains with wide input range 100-240 V AC, 50-60 Hz
or
• 12-24 V DC direct external power supply
Maximum consumption
• 1 A max on mains in 240 V AC
• 2 A max on mains in 100 V AC
• 16 A max on DC power supply
Power supply protection
• mains: fuse integrated into the 6.3 AT convertor (not accessible)
• external DC power supply:
- 1 fuse 20 A / 32 V DC on "+" wire,
- 1 fuse 30 A / 32 V DC on "-" wire.