background image

 

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                            www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No.D199-00-101-IS 

Issue 1        13-07-16                         Sheet 1 of 4

 

                                                           

INSTRUCTION MANUAL (ATEX / IECEx) 

STExL1 & STExL2 Loudspeakers

 

For use in Flammable Gas and Dust Atmospheres

 

 

 

 

 

 

 

 

 

 

1) Warnings 

 DO NOT OPEN WHEN AN EXPLOSIVE 

ATMOSPHERE IS PRESENT 

 POTENTIAL ELECTROSTATIC CHARGING 

HAZARD 

 ALL ENTRIES M20 X 1.5 - IF TEMPERATURE 

EXCEEDS 70°C AT ENTRY OR 80°C AT 
BRANCHING POINT USE SUITABLE RATED 
CABLE AND CABLE GLANDS 

 

2)  Rating & Marking Information 

 

All units have a rating label, which carries the following 
important information:- 

 

Input Voltage:    

Low Impedance Units  8

 or 16

 

Line Voltage Units 

70Vline or 100V line

 

 

STExL1 Codes

:  

 

 

Ex db IIC Gb T6 Ta -50°C to +55°C 

 

Ex db IIC Gb T5 Ta -50°C to +70°C 

 

Ex tb IIIC Db T95°C Ta -50°C to +70°C 

 

STExL2 Codes

:  

 

 

Ex db IIC Gb T6 Ta -50°C to +45°C 

 

Ex db IIC Gb T5 Ta -50°C to +60°C 

 

Ex db IIC Gb T4 Ta -50°C to +70°C 

 

Ex tb IIIC Db T105°C Ta -50°C to +70°C 

 

Certificate No.

     DEMKO 16 ATEX 1466X 

  IECEx 

ULD 

16.0017X 

 

       

 

 

 

 

 
 
 
 
 

The units can be installed in locations with the following 
conditions:

 

 

Area Classification Gas: 

Zone 1 

Explosive gas air mixture likely to occur in 
normal operation. 

Zone 2 

Explosive gas air mixture not likely to occur 
in normal operation, and if it does, it will 
only exist for a short time. 

 

 

Gas Groupings: 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

 

 

Temperature Classification: 

T1 450ºC 

 

T2 300ºC 
T3 200ºC 
T4 135ºC 

T5 

100ºC (up to 60ºC ambient for STExL2 

only) 

T6 

85ºC (up to 55ºC ambient for STExL1, up 

to 45ºC ambient for STExL2 only) 

 

Area Classification Dust: 

Zone 21 

Explosive dust air mixture likely to occur in 
normal operation. 

Zone 22 

Explosive dust air mixture not likely to 
occur in normal operation, and if it does, it 
will only exist for a short time. 

 

Dust Groupings: 

Group IIIA 

Combustible Flyings 

Group IIIB 

Non-conductive Dust 

Group IIIC 

Conductive Dust 

 

Ambient Temperature Range:

      -50

°

C to +70

°

C    

 

IP Rating:

 IP66 to EN/IEC60079-0 and EN/IEC60529 

 

Equipment Category:

 2G/D 

 

Equipment Protection Level:

  

Gb, Gc, Db, Dc 

 

Maximum Surface Temperature for Dust Applications: 

95ºC  

(STExL1) 

105ºC (STExL2) 

 

0518 

II  2G 
II  2D 

Epsilon x 
Equipment Group and 
Category: 

CE Marking 
Notified Body No. 

STExL1

 

STExL2

 

Отзывы: