European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]                Tel: +44 (0)20 8743 8880 

                                                                                                                                                             www.e2s.com               Fax: +44 (0)20 8740 4200 
Document No. IS 5002      Issue G             25-01-2018                       Sheet 2 of 4

 

SPECIAL  CONDITIONS  FOR  SAFE  USE  (as  stated  in  the 
EC Type Examination Certificate SIRA 05ATEX2084X)

 

Conditions for IS-mBl Beacon 

 

The  equipment  has  an  ingress  protection  rating  of  IP65. 
However, if it has been supplied without cable entry devices, 
then the user shall ensure that the devices that are fitted will 
provide  an  ingress  protection  that  is  appropriate  to  the 
environment in which it is installed i.e. IP20 or better. If only 
one of the two cable entries are used, then the unused entry 
'knockout'  shall  be  left  intact  or  fitted  with  a  blanking  device 
that  ensures  ingress  protection  appropriate  to  the 
environment in which it is installed i.e. IP20 or better. 
 

The  enclosure  is  non-conducting  and  may  generate  an 
ignition-capable level of electrosatic charges under certain 
extreme  conditions.  The  user  should  ensure  that  the 
equipment  is  not  installed  in  a  location  where  it  may  be 
subjected to external conditions that might cause a build-
up  of  electrostatic  charges  on  non-conducting  surfaces, 
additionally,  cleaning  of  the  equipment  should  be  done 
only with a damp cloth.

 

 

4.2  Zones, Gas Groups and T Rating

 

The IS-mB1 LED beacon has been certified Ex ia IIC T4 Ga.   
When  connected  to  an  approved  system  it  may  be  installed 
in: 
 
 

Zone 0 

explosive gas air mixture 

 

continuously present. 

 
 

Zone 1 

explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

 
 

Zone 2 

explosive  gas  air  mixture  not  likely  to  occur, 
and if it does, it will only exist for a short time. 

 
 
Be used with gases in groups: 
  

 

Group 

propane 

 

Group 

ethylene  

 

   

Group 

hydrogen 

 

 
Having a temperature classification of: 
 

T1 

450ºC 

T2 

300ºC 

T3 

200ºC 

T4 

135ºC 

 

4.3  Ter and -  power supply 

Power is supplied to the beacon via ter and - which 
have maximum input safety parameters of: 
 
 

Ui 

28V 

 

Ii 

 

660mA 

 

Pi 

 

1.2W 

 
 

Ci = 0 

 

Li = 0 

 
IS-mB1 beacons may be powered from ATEX certified Zener 
barriers  or  galvanic  isolators  certified  by  an  EC  Approved 
Body  which  have  output  parameters  equal  to  or  less  than 
28V, 660mA and 1,2W 
 
Up  to  three  IS-mB1  beacons  can  be  connected  in  parallel 
and be powered from a common barrier or isolator.   Parallel 

connection of beacons will significantly reduce the brightness 
of each device.  
 
The  maximum  permitted  cable  parameters  defined  by  the 
barrier or isolator certificate must not be exceeded. 
 

 

IS

-m

B

1

 B

e

a

c

o

n

Flash Rate
Header Pins

Input Terminals

 +

  

 -

'O' Ring Seal

2

H

  

1

H

z

  

  

F

la

s

h

 R

a

te

 

 
Fig 1  Location of field terminals and controls. 
 

5. INSTALLATION 

In addition to the certification requirements shown in section 
4.2,  the  environmental  conditions  must  be  within  the  limits 
shown  on  the  product  specification.    The  beacon  enclosure 
provides  IP65  protection  and is suitable  for  installation in an 
exterior location if an appropriate sealed cable entry is used. 
IS-mB1  beacons  should  only  be  installed  by  trained 
competent personnel. 
 

5.1 Mounting

 

The  IS-mB1  minialite  beacon  may  be  secured  to  any  flat 
surface by inserting two mounting screws through the back of 
the  round  base  (see  figure  2).  The  enclosure  provides  IP65 
protection  and  is  suitable  for installation  in  exterior  locations 
provided  that  the  area  around  the  two  mounting  screws 
through the back of the base moulding has been sealed and 
that  suitable  cable  glands  with  the  required  IP  rating  have 
been  used.  The  lens  should  be  aimed  towards  the  area 
where maximum visibility is required. 

 
5.2  Installation procedure 
 

a.  Unscrew  the  beacon  unit  security  screw  and  remove 

the  beacon  section  from  the  base  by  turning  it  anti-

clockwise.  Ensure  that  the  ‘O’  ring  seal  remains  in 

place. 

  

b.  Remove  the  required  20mm  knockout  section(s) 

depending on system wiring and mount the base to a 

flat  surface  by  inserting  two  screws  through  the  back 

of the base.  

 

c.  Fit  the  required  number  of  20mm  cable  glands  or 

conduit  entries  into  the  base  and  connect  the  field 

wiring to the appropriate beacon terminals as shown 

in section 6 and Fig 1 of this manual.  

 

d.  Check that the ‘O’ ring seal is correctly located on the 

beacon  section  (see  Fig.  1)  and  insert  the  beacon 

section  into  the  base.  Push  it  fully  home  and  turn  it 

clockwise to align the mouldings before tightening the 

security screw. 