Document D150-00-551-IS   Issue 4  11-08-2022 

 

 

Sheet 1 of 2 

 

 

 

www.e2s.com  Fax +44 (0)208 740 4200 

INSTRUCTION MANUAL 

IS-CP4B-BG Break Glass Manual Call Point 

For use in Flammable Gas Atmospheres 

IS-CP4B-BG 

Manual  Call  Point  –  Break  Glass 
With Resistor Modules 

For use in Flammable Gas and 
Combustible Dust Atmospheres. 
 

 

1) 

Introduction 

The IS-CP4B-BG is a breakglass manual call point 
which is  certified intrinsically safe to the European 
and  International  Gas  standards.  The  unit  meets 
the requirements of the ATEX directive 2014/34/EU 
and IECEx scheme. 
 
The  call  point  can  be  used  in  hazardous  areas 
where potentially flammable gas atmospheres may 
be present. 
 
The  IS-CP4B-BG  has  up  to  two  monitoring 
resistors.  The  units  are  Group  II,  EPL  (equipment 
protection level) Ga. The equipment is certified ‘Ex 
ia IIC T4 Ga’ and as such may be used in Zones 0, 
1  and  2  with  flammable  gases  and  vapours  with 
gas  groups IIA,  IIB & IIC and temperature classes 
T1, T2, T3 and T4. 
 
The equipment needs to be installed with ATEX 
and/or IECEx certified Zener Barriers or Galvanic 
Isolators. 
 
 
 

2) 

Marking 

All  units  have  a  rating  label,  which  carries  the 
following important information:- 
 
 
Unit Type No.: 
IS-CP4B-BG Manual Call Point 
 
Code: 
Ex ia IIC T4 Ga 
IP66 
 
Ui=30V Ii=500mA Pi=1.1W Ci=0 Li=0 
 
–40ºC <= Ta <= +50ºC 
 
Certificate No.: 
SIRA 09ATEX2287X 
IECEx SIR 09.0122X 
CSAE 21UKEX2555X 
 
Epsilon x:                           II 1G2D 
 
 
CE Marking 
Notified  

  

2813 

Body No.               
 
UKCA Marking 
Notified Body No.

 

0518 

 
 
Year/Serial No. i.e. 10/1CP4BBG000001   
 
WARNING - DO NOT OPEN WHEN AN 
EXPLOSIVE ATMOSPHERE MAY BE PRESENT 

 
3) 

Type Approval Standards 

The  beacon  has  an  EC  Type  examination 
certificate issued by SIRA and have been approved 
to the following standards:- 
 
EN IEC 60079-0:2018 / IEC 60079-0:2017 
EN 60079-11:2012 / IEC 60079-11:2011 
IEC 60079-26:2014 
 
The equipment is certified for use in ambient 
temperatures in the range -40

o

C to +50

o

C and shall 

not be used outside this range. 
 
 
 
 
 

4) 

Installation Requirements 

 Installation of this equipment shall only be carried 
out  by  suitably  trained  personnel  in  accordance 
with the applicable code of practice e.g.  
IEC 60079-14/EN 60079-14. 

 

Repair of this equipment shall only be carried out 
by the manufacturer or in accordance with the 
applicable code of practice e.g. IEC 60079-19/EN 
60079-19. 
 
The  certification  of  this  equipment  relies  on  the 
following materials used in its construction: 
 
Enclosure:

 

Aluminium  Pressure  Die  Cast  Body 

LM6 
 
Through enclosure mechanism: Plastic Nylon Zytel 
Injection Moulded 
 
Sealing  of  enclosure  and  mechanism:  O-ring 
Acrylonitrile-Butadiene Rubber  
 
If the equipment is likely to come into contact with 
aggressive substances,  then it is the  responsibility 
of the user to take suitable precautions that prevent 
it from being adversely affected, thus ensuring that 
the type of protection is not compromised. 
 
“Aggressive  substances”  -  e.g.  acidic  liquids  or 
gases that may attack metals, or solvents that may 
affect polymeric materials. 
 
“Suitable precautions” - e.g. regular checks as part 
of  routine  inspections  or  establishing  from  the 
material’s  data  sheet  that  it  is  resistant  to  specific 
chemicals. 
 
Refer  to  certificates  SIRA  09ATEX2287X  and 
IECEx SIR 09.0122X for special conditions of safe 
use. 
 

5) 

Call Point Location and Mounting 

The location of the call point should enable ease of 
access  for  operation  and  testing.  The  unit  should 
be  mounted  using  the  4  off  fixing  holes  which  will 
accept up to M4 sized fixings. 
 
When installing in Zone 0 applications, ensure that 
the equipment enclosure is protected from impact. 
 

 

 
View of base unit showing fixing centres. 
 
 
To  gain  access  to  the  mounting  holes  in  the  base 
the front cover must be removed.  
This  is  achieved  by  removing  the  4  off  M4  cap 
head bolts holding on the cover. 
 

 

 
Once the screws are removed the cover will hang 
down out of the way to gain access to the Ex e 
terminal block, the internal earth terminal and 
mounting hole recesses.

 

Содержание IS-CP4B-BG

Страница 1: ...is certified for use in ambient temperatures in the range 40o C to 50o C and shall not be used outside this range 4 Installation Requirements Installation of this equipment shall only be carried out...

Страница 2: ...test key 7mm Allen key is used to mechanically drop the glass down activating the switch The test key is inserted in the test cam and rotated clockwise by an angle of 60 the glass element will visibl...

Страница 3: ...CALL POINT BExCP3B C D PB PUSH BUTTON MANUAL CALL POINT BExCP3B C D PT TOOL RESET MANUAL CALL POINT IS CP4B BG BREAK GLASS MANUAL CALL POINT IS CP4B PB PUSH BUTTON MANUAL CALL POINT IS CP4B PT TOOL R...

Страница 4: ...a 55 C II 2D Ex tb IIIC T60 C Db 40 C Ta 55 C IP6X Dust Protection to EN60079 0 EN60079 31 IS CP4B II 1G Ex ia IIC T4 Ga 40 C Ta 55 C BEx CP5B II 2D Ex tb IIIC T70 C Db 40 C Ta 50 C IP6X Dust Protecti...

Страница 5: ...and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Страница 6: ...Dust Protection to EN60079 0 EN60079 31 IS CP4B II 1G Ex ia IIC T4 Ga 40 C Ta 55 C BEx CP5B II 2D Ex tb IIIC T70 C Db 40 C Ta 50 C IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC...

Страница 7: ...and Place of Issue London 04 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Отзывы: