background image

warning signals

2S

D1x

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000
GEOMETRIC TOLERANCES TO ISO1101:1983
LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 
DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D190-06-651

R.S.RAIT

B.ISARD

R.N.POTTS

OF

NTS 1

2

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  
RECOMMENDED VALUE FOR SIL 2 EOL = 2.2K

 2.0W

MINIMUM EOL RESISTOR VALUES FOR 28VDC MAX VOLTAGE
500

 MIN AT 2W MIN OR 2.4K

 MIN AT 0.5W MIN

EO

L

Stage 1 +ve IN

Stage 1 +ve OUT

Common -ve IN

Common -ve OUT

Stage 2 +ve

Stage 1 +ve IN

Stage 1 +ve OUT

Common -ve IN

Common -ve OUT

Stage 2 +ve
Stage 3 +ve

EOL

+

-
-

+

EOL

+

-
-

+

S2

EOL

+

-
-

+

S2
S3

Stage 1 +ve IN

Stage 1 +ve OUT

Stage 1 -ve IN

Stage 1 -ve OUT

Single Stage Configuration

                         Config.: 1a

Line Monitoring
Set to positive switching (default)
Stage 1: Apply Power to Stage 1 +ve & Stage 1 -ve
For full 4-Wire SIL 2 Connection Monitor SIL 2 +ve and SIL 2 -ve 

Terminals 1 & 2 in RLY1-2

Two Stage Configuration

             Config.: 1b

Common Negative
Set to positive switching (default)
Stage 1: Apply Power to Stage 1 +ve & Common -ve 
Stage 2: Apply Power to Stage 2 +ve & Common -ve

For full 4-Wire SIL 2 Connection Monitor SIL 2 +ve and SIL 2 -ve 

Terminals 1 & 2 in RLY1-2

Three/Four Stage Configuration

      Config.: 1c

Common Negative
Set to positive switching (default)
Stage 1: Apply Power to Stage 1 +ve & Common -ve
Stage 2: Apply Power to Stage 2 +ve &Common -ve 
Stage 3: Apply Power to Stage 3 +ve &Common -ve
Stage 4: Apply Power to Stage 2 +ve, Stage 3 +ve & Common -ve

For full 4-Wire SIL 2 Connection Monitor SIL 2 +ve and SIL 2 -ve 

Terminals 1 & 2 in RLY1-2

19/09/2022

19/09/2022

19/09/2022

    D1xS1 / D1xS2 / GNExS1 / GNExS2 / STExS1 / 

STExS2 SIL 2 DC SOUNDER WIRING DIAGRAMS

INTRODUCTION

INTRODUCTION

1

RSR - 19/09/2022

SIL 2 +ve IN

SIL 2 -ve OUT

+
-

+
-

+
-

4 - WIRE SIL RLY1-2

4 - WIRE SIL RLY1-2

SIL 2 +ve IN

SIL 2 -ve OUT

4 - WIRE SIL RLY1-2

SIL 2 +ve IN

SIL 2 -ve OUT

Содержание GNExS2FDC024-S

Страница 1: ...evel P3 dB A P2 P3 P2 P3 Max Nom Max Nom GNExS2FDC024 S 24Vdc 20 28Vdc 324mA 740mA 324mA 740mA 120 115 123 118 GNExS2HDC024 S 24Vdc 20 28Vdc 324mA 740mA 324mA 740mA 124 119 127 122 Max Tone 4 Nom Tone...

Страница 2: ...cate No SIRA 13ATEX1139X IECEx SIR 13 0029X CSAE 21UKEX1558X Epsilon x Equipment Group and Category II 2G CE Marking and Notified Body No 2813 UKCA Marking and Notified Body No 0518 4 Zones Gas Group...

Страница 3: ...clean and that they have not been damaged during installation Ensure that the O ring seal is in place and undamaged When fitting the flameproof cover ensure the thread is engaged correctly Fully tigh...

Страница 4: ...ranching point temperatures may exceed 70 C at entry point 80 C at branching point Therefore suitable heat resisting cables and cable glands must be used with a rated service temperature at least as s...

Страница 5: ...switching Figure 9 Stage Switching Polarity 8 3 Tone Selection The ExS Alarm Horn Sounders have 64 different tones that can be selected independently for the first and second stage alarms The tones ar...

Страница 6: ...ms and a minimum wattage of 2W The resistor must be connected directly across the ve and ve terminals as shown in the following drawing The resistor leads should be kept as short as possible SIL2 line...

Страница 7: ...SIL 2 Sounder Unit Monitors Standby mode and Active mode Health status of power supply Sounder correct function and tone pattern The SIL 2 sounder operates as part of a SIL 2 system The sounder will a...

Страница 8: ...quire further investigation please contact your local E2S representative Commissioning System Functional start up of System Normally in reverse polarity mode When Commissioning system the power must n...

Страница 9: ...ounder check on pattern generation and signal output checks Important Only tones use tones that are stated as SIL 2 approved for the SIL 2 application Ensure that the unit is set to one of these tones...

Страница 10: ...rom the circuit Note a cable short circuit will not be detectable in this configuration For one unit only Sounder power supply terminal block Current drawn mA Active Mode 190mA Standby Mode 25mA SIL2...

Страница 11: ...multiple SIL 2 alarm horn sounders are to be cabled in series the monitoring connections differ from that of a single alarm horn sounder For more information see manual D197 00 651 IS available from t...

Страница 12: ...ion B pins 2 3 linked Places power supply terminal Fault resistor RLY 1 2 in circuit As used in 2 Wire Configuration Figure 17 J2 Header pin positions Fault Resistor FR 15 4 SIL 2 Hard Reset Function...

Страница 13: ...nput GNExS2FDC024 S GNExS2HDC024 S Failure to Sound Integrity in respect of failure to release SIL 2 Total Failure rate 0 447 pmh hazardous failure rate revealed 0 443 pmh hazardous failure rate unrev...

Страница 14: ...The values of resistors available are shown in table 6 below Code Resistor Value Default resistor coding as follows GNExS2FDC024AB1S1R AFZ Example of a custom requirement resistor coding GNExS2FDC024...

Страница 15: ...0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1...

Страница 16: ...OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve EOL EOL S2 EOL S2 S3 Stage 1 ve IN Stage 1 ve OUT Stage 1 ve IN Stage 1 ve OUT...

Страница 17: ...S NTS SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED Stage 2 ve Common ve IN Common ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 OF 2 2 EOL S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUP...

Страница 18: ...y No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIB or IIC T...

Страница 19: ...te and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Страница 20: ...ipment II 2G Ex db IIB or IIC T3 T4 T5 or T6 Gb Standards applied EN 60079 0 2018 EN 60079 1 2014 A C 2018 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6...

Отзывы: