European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D209-00-001-IS

 

Issue 1

 

20-08-22

 

 

Sheet 5 of 5

 

 

The resistor must be connected directly across the +ve and  
-ve terminals as shown in the following drawing. Whilst 
keeping its leads as short as possible, a spacing of at least 
1/16” (1.58mm) must be provided through air and over 
surfaces between uninsulated live parts. 

 

 

 

Fig. 8 End of Line Resistor Placement 

 

11) Settings 

 

11.1 

Tone Selection 

 

The sounders have 45 different tones that can be selected for 
the first stage  alarm.  The  sounders  can  then be  switched  to 
sound  second  and  third  stage  alarm  tones.  The  tones  are 
selected by operation of a DIP switch on the PCB for both DC 
and  AC  units.  The  tone  table  on  page  six  shows  the  switch 
positions  for  the  45  tones  and  which  tones  are  available  for 
the  second  and  third  stages.  To  operate  the  sounder  on 
stage  1  simply  connect  the  supply  voltage  to  the  normal 
supply  terminals  (+ve  and  –ve  for  DC units, L  and  N for AC 
units). 

 

11.2 

Volume Control 

 

 

The output level of the E2x sounder can be set by adjusting 
the volume control potentiometer (see Fig 4 for AC & Fig 6 for 
DC).  For  maximum  output,  set  the  potentiometer  fully 
clockwise. 

 

12) Maintenance, Overhaul & Repair 

 

Maintenance,  repair  and  overhaul  of  the  equipment  should 
only  be  carried  out  by  suitably  qualified  personnel  in 
accordance with the current relevant standards: 

 

EN60079-19 
IEC60079-19 

Explosive atmospheres - Equipment repair, 
overhaul and reclamation 

 

EN 60079-17 
IEC60079-17 

Explosive atmospheres - Electrical 
installations inspection and maintenance 

 

To  avoid  a  possible  ELECTROSTACTIC  CHARGE  the  unit 
must only be cleaned with a damp cloth. 

 

Units must  not  be  opened  while an  explosive  atmosphere  is 
present. 

 

If  opening  the  unit  during  maintenance  operations  a  clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 

 

Fig. 9 Dip Switch 

 

1=ON; 0=OFF Example shown: 100000 = Tone 2 (Default 

setting) 

 

13) Tone Table 

45

Tone 34

Tone 38

0  0  1  1  0  1

1KHz 1s on, 1s off Intermittent

PFEER Gen. Alarm

Tone 5

Tone 2

1  1  0  1  0  1

Motor Siren - slow rise to 2400Hz

44

Tone 5

Tone 2

0  1  0  1  0  1

1200Hz Continuous

43

Tone 5

Tone 2

1  0  0  1  0  1

Motor Siren - slow rise to 800Hz

42

Tone 5

Tone 2

0  0  0  1  0  1

Motor Siren - slow rise to 1200Hz

41

Tone 27

Tone 31

1  1  1  0  0  1

544Hz (100mS)/440Hz (400mS)
- NF S 32-001

40

Tone 17

Tone 23

0  1  1  0  0  1

800Hz 0.25 sec on, 1 sec off Intermittent

39

Tone 45

Tone 34

1  0  1  0  0  1

2000Hz Continuous

38

Tone 45

Tone 9

0  0  1  0  0  1

1000Hz Continuous - 

PFEER Toxic Gas

37

Tone 5

Tone 35

1  1  0  0  0  1

500-1200Hz 3.75 sec /0.25 sec 

Australian Evac.

36

Tone 5

Tone 36

0  1  0  0  0  1

420Hz @ 0.625 Sec Australian Alert

35

Tone 45

Tone 38

1  0  0  0  0  1

1000 & 2000Hz @ 0.5 sec 

Aletrnating - Signapore

34

Tone 5

Tone 2

0  0  0  0  0  1

745Hz @ 1Hz Intermittent

33

Tone 15

Tone 26

1  1  1  1  1  0

Two tone chime

32

Tone 5

Tone 26

0  1  1  1  1  0

660/1200Hz @ 1Hz Sweeping

31

Tone 5

Tone 2

1  0  1  1  1  0

300Hz Continuous

30

Tone 5

Tone 7

0  0  1  1  1  0

800/1000Hz @ 7Hz Sweeping

29

Tone 5

Tone 2

1  1  0  1  1  0

440Hz Continuous

28

Tone 5

Tone 26

0  1  0  1  1  0

554Hz Continuous

27

Tone 15

Tone 2

1  0  0  1  1  0

Bell

26

Tone 5

Tone 29

0  0  0  1  1  0

2400/2900Hz @ 50Hz Sweeping

25

Tone 5

Tone 29

1  1  1  0  1  0

800/1000Hz @ 50Hz Sweeping

24

Tone 5

Tone 6

0  1  1  0  1  0

800Hz @ 2Hz Intermittent

23

Tone 5

Tone 2

1  0  1  0  1  0

544Hz @ 0.875 sec Intermittent

22

Tone 5

Tone 2

0  0  1  0  1  0

554Hz/440Hz @ 1Hz Alternating

21

Tone 5

Tone 2

1  1  0  0  1  0

660Hz Continuous

20

Tone 5

Tone 2

0  1  0  0  1  0

1.4KHz - 1.6KHz 1s, 1.6KHz - 1.4 
KHz 0.5s - NFC48-265

19

Tone 5

Tone 2

1  0  0  0  1  0

660Hz 1.8 sec on, 1.8 sec off Intermittent

18

Tone 27

Tone 2

0  0  0  0  1  0

544Hz (100mS)/440 Hz (400m/S)
- NF S 32-001

17

Tone 5

Tone 18

1  1  1  1  0  0

660Hz 150mS on, 150mS off Intermittent

16

Tone 5

Tone 2

0  1  1  1  0  0

800Hz Continuous

15

Tone 5

Tone 4

1  0  1  1  0  0

800Hz 0.25 sec on, 1 sec off Intermittent

14

Tone 5

Tone 15

0  0  1  1  0  0

2400Hz @ 1Hz Intermittent

13

Tone 5

Tone 4

1  1  0  1  0  0

800/1000Hz @ 0.875Hz Alternating

12

Tone 5

Tone 2

0  1  0  1  0  0

1000Hz @ 1Hz Intermittent

11

Tone 5

Tone 7

1  0  0  1  0  0

2400/2900Hz @ 2Hz Alternating

10

Tone 2

Tone 15

0  0  0  1  0  0

1200/500Hz @ 1Hz - DIN 

PFEER P.T.A.P.

9

Tone 5

Tone 2

1  1  1  0  0  0

500/1200/500Hz @ 0.3Hz Sweeping

8

Tone 5

Tone 10

0  1  1  0  0  0

2400/2900Hz @ 1Hz Sweeping

7

Tone 5

Tone 7

1  0  1  0  0  0

2400/2900Hz @ 7Hz Sweeping

6

Tone 20

Tone 3

0  0  1  0  0  0

2400Hz Continuous

5

Tone 5

Tone 6

1  1  0  0  0  0

800/1000Hz @ 1Hz Sweeping

4

Tone 5

Tone 2

0  1  0  0  0  0

500/1200Hz @ 0.3Hz sec
Slow Whoop

3

Tone 5

Tone 17

1  0  0  0  0  0

800/1000Hz @ 0.25 sec Alternating

2

1  2  3  4  5  6

Tone 5

Tone 2

0  0  0  0  0  0

340Hz Continuous

1

Stage 3

Stage 2

Switch

Frequency Description

Stage 1

 

 

 

Warning - High noise levels above 85dB(A) 
during  operation.  High  levels  of  noise  may 
cause  hearing  loss,  wear  suitable  ear 
protection when equipment is in operation.

 

End of Line Resistor 

Содержание E2xS1F

Страница 1: ...ON HUMIDE HAUT TENSION RISK DE CHOC ATTENDEZ 5 MINUTES APRES AVOIR DEBRANCHE L ALIMENTATION AVANT D OUVRIR LA BOITIER 3 Rating Marking Information 3 1 ATEX IECEx UKEx certification The E2xS1 alarm hor...

Страница 2: ...l Electric Code CEC Class Zone ratings Canada Standards CAN CSA C22 2 No 60079 0 Ed 4 02 2019 Explosive Atmospheres Part 0 Equipment General Requirements CAN CSA C22 2 No 60079 7 Ed 2 Explosive Atmosp...

Страница 3: ...d certified cable entry and or blanking devices during installation Equipment with the flare horn shall not be installed with the flare higher than horizontal to avoid accumulation of dust The equipme...

Страница 4: ...nclosure See section 5 of this manual for access to the enclosure Wires having a cross sectional area between 0 5 mm to 2 5mm can be connected to each terminal way If an input and output wire is requi...

Страница 5: ...1 0 0 1 544Hz 100mS 440Hz 400mS NF S 32 001 40 Tone 17 Tone 23 0 1 1 0 0 1 800Hz 0 25 sec on 1 sec off Intermittent 39 Tone 45 Tone 34 1 0 1 0 0 1 2000Hz Continuous 38 Tone 45 Tone 9 0 0 1 0 0 1 1000...

Страница 6: ...IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D209 06 001 R S RAIT R N POTTS R N POTTS 05 08 2020 OF E2xS1R E2xS1F E2xS2F SOUNDER WIRING DIAGRAMS INTRODUCTION RSR 05 08 2020 NT...

Страница 7: ...Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standar...

Страница 8: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 9: ...on Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T4 T3 T2 Gc II 3D Ex tc IIIC 85 C 120 C Dc IP6X Dust Protection to EN60079 0 EN60079 31 Standards applied EN IEC 6007...

Страница 10: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: