European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D211-00-201-IS
Issue 1
20-08-22
Sheet 1 of 6
INSTRUCTION MANUAL
D2xB1X05 & D2xB1X10 Xenon Beacons
For use in Hazardous Locations
D2XB1X05
D2XB1X10
1) Product Table
2) Warnings
DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGISED
POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
NE PAS OUVRIR UN PRESENCE
D’ATMOSPHERE EXPLOSIVE
NE PAS OUVRIR ENERGIE
DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L’ALIMENTATION AVANT
D’OUVRIR LA BOITIER
3) Rating & Marking Information
All units have a rating label, which carries the following
important information:
•
Unit Model.
•
Voltage Range
•
Nominal Voltage
See Table 1 for electrical ratings of each Unit Model.
3.1. Fire Alarm Ratings
The Following models are certified as visual alarm devices for
private mode visual alarm devices in accordance with
UL1638 Fifth Edition / CAN/ULC-S526 Fourth Edition when
used with clear or red lens covers:
D2XB1X05DC024 ; D2XB1X05DC048
D2XB1X10DC024 ; D2XB1X10DC048
See fire instruction manual D211-00-201-IS-SC-UL
Model
Nom. Voltage
Voltage Range
Operating
rms Current
D2xB1X05DC024
24Vdc
20-28Vdc
296mA
D2xB1X05DC048
48Vdc
48Vdc
145mA
D2xB1X05AC115
115Vac
115-120Vac 50/60Hz
80mA
D2xB1X05AC230
230Vac
220-230Vac 50/60Hz
30mA
D2xB1X10DC024
24Vdc
20-28Vdc
609mA
D2xB1X10DC048
48Vdc
48Vdc
260mA
D2xB1X10AC115
115Vac
115-120Vac 50/60Hz
185mA
D2xB1X10AC230
230Vac
220-230Vac 50/60Hz
107mA
Table 1: Electrical Ratings.