7.3  Earthing 

Fig 4: Earth Locations 

The unit has both a primary internal and secondary external earth 
fixing point. 

Internal earthing connections should be made to the Internal Earth 
terminal in the base of the housing using a ring crimp terminal to 
secure the earth conductor under the earth clamp. The earth 
conductor should be at least equal in size and rating to the incoming 
power conductors but at least a mini mum of 0.82mm2 / 18AWG in 
size. 

External earth connections can be made to the M5 earth stud (see 
Fig. 4), using a ring crimp terminal to secure the earth conductor 
to the earth stud. The external earth conductor should be at least 
4mm

2

 in size. 

The external earth crimp ring should be  located between the two 
M5 plain washers provided and securely locked down with the M5 
spring washer and M5 nut. 

7.4 

Cable Glands, Blanking Elements & Adapters 

Ingress Protection 

If a high IP (Ingress Protection) rating is required then a  suitable 
sealing washer must be fitted under the cable glands or blanking 
plugs.  A  minimum  ingress  protection  rating  of  IP6X  must  be 
maintained for installations in explosive dust atmospheres. 

To maintain the ingress protection rating and mode of protection, 
the  cable  entries  must  be  fitted  with  suitably  rated  cable  entry 
and/or blanking devices during installation. 

If entries are fitted with adaptors they must be suitably rated for 
the application. Fitting of blanking elements into adaptors is not 
permitted. 

Adapters 

The D1x range can be supplied with the following types of adapters: 

M20 to ½” NPT 
M20 to ¾” NPT 
M20 to M25 

It  is  important  to  note  that  stopping  plugs  cannot  be  fitted  onto 
adapters, only directly onto the M20 entries. 

8) Settings

8.1  Accessing PCBAs 

SPL Configuration

 

Following  illustrations show the settings  available  for  D1xS1  UNITS. 
See  schematic  diagram  DC:  D190-06-201  or  AC:D190-06-205  for 
details. 

See  Table  1  for  product  power  supply  and  Sound  Pressure  Levels 
(SPL). 

Configuration for DC Units 

Figure 6: DC PCBA. 

Configuration for AC Units 

Figure 7: AC PCBA .

Internal Earth 
Marked with G 

External Earth 

Loosen thumbscrew 
before rotating 
beacon board 

Rotate beacon board 
to access sounder 
board 

(default) 

(default) 

Loosen thumbscrew 
before rotating 
beacon board 

Содержание D1xC1X05FAC115-D

Страница 1: ...0 60Hz D1xC2X05FAC230 D 230Vac P2 P3 157 246mA 220 240Vac 50 60Hz Max Tone 4 Nom Tone 44 The table shows the input current taken by the various sounders The current levels shown above are for the 440H...

Страница 2: ...nstallation must be carried out in compliance with the National Electric Code D1xC units have been tested and found suitable for use in atmospheres containing the following chemicals in accordance wit...

Страница 3: ...essing the enclosure To access the Ex d chamber loosen the M4 grub screw on the cover Open the enclosure by turning the cover counterclockwise and remove the cover On completion of the installation th...

Страница 4: ...uired then a suitable sealing washer must be fitted under the cable glands or blanking plugs A minimum ingress protection rating of IP6X must be maintained for installations in explosive dust atmosphe...

Страница 5: ...ferent tones that can be selected independently for the first and second stage alarms The tones are selected by operation of the tone setting DIP switch 1 DIP switch 2 see fig 10 on the PCB for stage...

Страница 6: ...06 305 for AC Schematic Diagrams 9 End of Line Monitoring DC Units 9 1 Standard DC End Of Line Monitoring All DC units have a blocking diode fitted in their supply input lines An end of line monitorin...

Страница 7: ...0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1...

Страница 8: ...age 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve WIRING LINKING BEACON SOUNDER FACTORY FITTED 6 R1 R1 S2 S3 R1 S2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX...

Страница 9: ...ED D190 06 301 6 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2W MIN OR 1K MIN 0 5W MIN 28V MAX SYSTEM 470 MIN 2W MIN OR 2 4K MIN 0 5W MIN RECOMMENDED MINI...

Страница 10: ...DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF 3 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D190 06 301 6 WIRING LINKING BEACON...

Страница 11: ...T Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve ve IN ve IN D190 06 301 6 4 R2 ve OUT ve OUT R1 R1 S2 R1 S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUP...

Страница 12: ...R2 R1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2W MIN OR 1K MIN 0 5W MIN 28V MAX SYSTEM 470 MIN 2W MIN OR 2 4K MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four S...

Страница 13: ...DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D190 06 301 6 6 OPTIONAL LINE MONITOR...

Страница 14: ...SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 305 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STA...

Страница 15: ...CALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 305 R S RAIT B ISARD R N POTTS OF NTS 2 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 2 Stage 1 Live...

Страница 16: ...Page left Intentionally blank...

Отзывы: