INSTRUCTION MANUAL
BExL15D & BExL25D
Loudspeakers
ATEx/IECEx & UKEx Gas & Dust
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D210-00-101-IS
Issue 6
12-09-2022
Sheet 1 of 5
BExL15D
BExL25D
1. Product Table
Unit Type Code
Input
Power
Max I/P Voltage
Sound
Pressure Level
dB(A)
Max*
Nom
.†
BExL15DFV070
70V Line
15W
70V
102dB(A) 113dB(A)
BExL15DFV100
100V Lie
15W
100V
BExL15DFR008
8Ω
15W
10.95
BExL15DFR016
16Ω
15W
15.49V
BExL25DFV070
70V Line
25W
70V
105dB(A)
119dB(A)
BExL25DFV100
100V Lie
25W
100V
BExL25DFR008
8Ω
25W
14.14
BExL25DFR016
16Ω
25W
20V
The table shows the input current taken by the various loudspeakers.
Nominal current at nominal voltage.
Table 1: Electrical Ratings.
It is important that the loudspeakers are connected to power amplifiers that have outputs that are compatible to the type of loudspeaker
being used. Loudspeakers with a 70V or 100V line matching transformer fitted must be connected to a power amplifier with a 70V or
100V line output. Low impedance 8 ohm or 16 ohm loudspeakers must be connected to amplifiers with a suitable low impedance
output.
The above table shows the maximum AC signal voltages at which the loudspeakers can be operated
The input current will vary according to the voltage input level and the frequency of the tone selected.
The current levels taken by the each loudspeaker will depend on which output tapping has been selected (see section 12 & 13 of this
instruction manual). BExL25D 70V and 100V Line units have output levels of 25W, 12.5W, 6W and 2W; BExL15D 70V and 100V Line
units have output levels of 15W, 7.5W, 3W and 1W.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C
Содержание BExL15D