background image

warning signals

2S

BEx

EUROPEAN SAFETY SYSTEMS LTD

IMPRESS HOUSE

MANSELL ROAD

ACTON

LONDON W3 7QH

WWW.E2S.COM

C

THIS DRAWING AND ANY INFORMATION OR DESCRIPTIVE 

MATTER THEREIN IS COMMUNICATED IN CONFIDENCE AND 

IS THE COPYRIGHT PROPERTY OF EUROPEAN SAFETY 

SYSTEMS LTD. NEITHER THE WHOLE OR ANY EXTRACT MAY 

BE DISCLOSED, LOANED, COPIED OR USED FOR 

MANUFACTURING OR TENDERING PURPOSES WITHOUT THEIR 

WRITTEN CONSENT.

EUROPEAN SAFETY SYSTEMS LTD.

AS PER LATEST DATE OF ISSUE SHOWN ABOVE

DRAWING TO BS8888:2000

GEOMETRIC TOLERANCES TO ISO1101:1983

LINEAR DIMENSIONAL TOLS

ANGULAR DIMENSIONAL TOLS

STANDARDS

MOD No.

REASON - INITIAL - DATE

ISSUE

DATE

APPROVED

CHECKED

DATE

DATE

DRAWN

WEIGHT (Kg)

SURFACE FINISH

MATERIAL

ALTERNATIVE MATERIAL

SHEET

SCALE

TITLE

A3

IF IN DOUBT, ASK - 

DO NOT SCALE

ALL DIMENSIONS IN MM

DRAWING NUMBER

A

B

C

D

E

F

G

10

9

G

F

E

7

8

6

5

D

C

1

3

4

2

A

B

D210-06-601

R.S.RAIT

B.ISARD

R.N.POTTS

OF

NTS

1

1

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  

 500Ω MIN, 2W MIN OR 3K3Ω MIN, 0.5W MIN

MINIMUM VALUES:

R1

Single Stage Configuration

                         Config.: 1a

Line Monitoring

Set to negative switching (default)

Stage 1: Apply Power to Stage 1 +ve & Stage 1 -ve

Two Stage Configuration

             Config.: 1b

Common Positive

Set to negative switching (default)

Stage 1:Apply Power to +ve & -ve

Stage 2: Apply Power to +ve & -ve, Connect Stage 2 to -ve

Stage 3: Apply Power to +ve & -ve, Connect Stage 3 to -ve

Three Stage Configuration

      Config.: 1c

Common Negative

Set to positive switching (Customer to set header pin)

Stage 1:Apply Power to +ve & -ve

Stage 2: Apply Power to +ve & -ve, Connect Stage 2 to +ve

Stage 3: Apply Power to +ve & -ve, Connect Stage 3 to +ve

08/03/2022

08/03/2022

08/03/2022

BExCS110-05D DC COMBINED SOUNDER

& BEACON WIRING DIAGRAMS

INTRODUCTION

INTRODUCTION

1

RSR - 05/09/2022

Stage 1 -ve

Stage 1 +ve

Stage 2

-ve

+ve

Stage 3

Set to Positive Switching

R1

R1

Stage 2

+ve

-ve

Stage 3

R1

SWITCHES FOR STAGE OPERATION

CUSTOMER SUPPLIED

Stage 1 -ve in

Stage 1 +ve in

Stage 1 +ve out

Stage 1 -ve out

Stage 1 -ve in

Stage 1 +ve in

Stage 1 +ve out

Stage 1 -ve out

Stage 1 -ve in

Stage 1 +ve in

Stage 1 +ve out

Stage 1 -ve out

WIRING LINKING BEACON & 

SOUNDER FACTORY FITTED

Содержание BExCS110-05D-P

Страница 1: ...05DPAC230 BExCS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440Hz Continuous to...

Страница 2: ...air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Application...

Страница 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Страница 4: ...section of the unit Fig 3 Internal View of Cover When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal ear...

Страница 5: ...m power rating of 0 5 watts or a minimum resistance value of 500 and a minimum power rating of 2 watts The resistor must be connected directly across the ve and ve terminals as shown in the following...

Страница 6: ...sounder on stage one simply connect the supply voltage to the normal supply terminals ve and ve for DC units L and N for AC units Refer to wiring schematics D210 06 601 DC or D210 06 605 AC Default To...

Страница 7: ...Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive at...

Страница 8: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Страница 9: ...Page left Intentionally blank...

Страница 10: ...ER SUPPLIED 500 MIN 2W MIN OR 3K3 MIN 0 5W MIN MINIMUM VALUES R1 Single Stage Configuration Config 1a Line Monitoring Set to negative switching default Stage 1 Apply Power to Stage 1 ve Stage 1 ve Two...

Страница 11: ...RFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 605 R S RAIT B...

Страница 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Страница 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Страница 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Страница 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Страница 16: ...Page left Intentionally blank...

Отзывы: