INSTRUCTION MANUAL
BExBGL2D-P
LED Beacon
ATEx/IECEx & UKEx Gas & Dust
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D210-00-401-IS
Issue 6
12-09-2022
Sheet 1 of 6
BExBGL2D-P
1. Product Table
Unit Type Code
Nominal
Input Voltage
Nominal
Input Current
Max I/P Voltage
BExBGL2DPDC024
24Vdc
240mA
54Vdc
BExBGL2DPAC115
115Vac
95mA
126Vac 50/60Hz
BExBGL2DPAC230
230Vac
48mA
253Vac 50/60Hz
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various beacons and shows the maximum voltage at which the beacons can be
operated:
The input current will vary according to the voltage input level.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C