12) SIL 2 Instruction/Safety Manual

 

Fig 4 - The SIL 2 Module monitors the Beacon and interfaces to the customer plant. 

Warning

 

– 

To  maintain  the  integrity  of  the  SIL  2  units  the  system  must  be  installed  in  accordance  with  this  manual.  Any 

deviation could result in failure of the SIL 2 system and an unintended unit operation or function. 

 

Warning

 

– 

Unit must be installed, commissioned and used within the parameters outlined in this manual. Failure to comply 

with this will result in potential unit failure within the system. 

 

Warning

 

– 

The unit must be powered in either Standby or Active modes to comply with the SIL 2 approval requirement. 

 

Warning

 

– 

If the power is disrupted the unit must be allowed to go through the commissioning cycle to reset, if this does not 

happen and the power continues to be disrupted the unit will latch the fault and require a hard system reset. 

 

SIL 2 System Description 

The  E2S  BEx  range  of  IECEx  &  ATEX  compliant  signaling 
devices with integrated SIL 2 fault monitoring modules.  

 

The  SIL  2  module  monitors  the  function  of  the  device  and 
provides  feedback to  the  control panel.  A  fault  condition can 
be  communicated  via  independent  fault  contacts  or  by  the 
introduction to the monitoring circuit of an end of line resistor. 
A SIL 2 system wiring for fault detection in standby and active 
mode 

– 4 wire installation can be seen as per section 14.1. A 

SIL  2  system  wiring  for  fault  detection  in  standby  and  active 
mode 

– 2 wire installation can be seen as per section 14.2. 

 

The new SIL 2 version of the E2S BExS110-SIL & BExS120-
SIL  alarm  horn  sounder  and  BExBG05-SIL,  BexBG10-SIL  & 
BexBG15-SIL Xenon strobe beacon are designed, tested and 
certified, bringing plant safety to new levels. 

 

Key benefits: 

 

Signaling 

device 

function 

is 

checked 

and 

automatically reported to the control panel. 

 

Eliminates  the  need  for  time  consuming  physical 
inspections. 

 

Increased  plant  safety,  confidence  that  all  devices 
are fully functioning. 

 

Designed  to  integrate  seamlessly  into  your  SIL  2 
environment. 

 

 
 
 

13) SIL 2 System Terms and Function 

 
The SIL 2 Beacon Unit Monitors 

 

Standby mode and Active mode 

 

Health status of power supply 

 

Beacons correct function and flash pattern 

 

 

The SIL 2 beacon operates as part of a SIL 2 system. 
The  beacon  will  after  commissioning  remain  powered  in 

Standby mode

 (reverse polarity) until the beacon is required 

to  operate.  When  the  signaling  device is required to  operate 
beacon the polarity is changed back to normal supply and the 
beacon  will  go  into 

Active  mode

  where  it  will  start  to 

function/flash.  When  testing  the  system  and  beacons 
operation, the system is put into 

Active mode

 
The customer PLC will control whether the system is in either 
of the main two operational modes. 

 
 
 
 
 
 

Содержание BExBG10D-P-SIL

Страница 1: ...EX2006X IECEx KEM 10 0002X The BExBG10D and BExBG15D beacons have been certified for use in locations with the following conditions Area Classification Gas Zone 1 Explosive gas atmosphere likely to oc...

Страница 2: ...location of the beacons should be made with due regard to the area over which the warning signal must be visible They should only be fixed to services that can carry the weight of the unit SAFETY WAR...

Страница 3: ...or use in explosive dust atmospheres a minimum ingress protection rating of IP6X must be maintained The BEx beacon range can be supplied with the following types of adapters M20 to NPT M20 to NPT M20...

Страница 4: ...the control panel A fault condition can be communicated via independent fault contacts or by the introduction to the monitoring circuit of an end of line resistor A SIL 2 system wiring for fault dete...

Страница 5: ...re and may not be functioning correctly 13 2 Power Failure SIL 2 Failure SIL 2 Controller failure Internal function and system checking flags fault Rapid Power cycling System indicates power instabili...

Страница 6: ...be seen via the SIL 2 TB1 terminals as soon as the fault occurs in either Active or Standby modes As factory default when there is no fault the TB1 terminals 1 2 will be closed putting a 3 3k current...

Страница 7: ...he default customer sense resistor value is 3 3k Examples of calculations of resistance for steady mode and fault mode are shown in table 1 Panel Resolution Topology Resistor TB1 CSR No of Units Stead...

Страница 8: ...units default position is A Figure 7 Schematic of SIL 2 system wiring for fault detection in standby mode only 2 wire installation To evaluate the total current drawn from the SIL 2 unit use the equa...

Страница 9: ...e customer can select a system EOL resistor The default fault resistor value is 2 2k which is recommended and is fitted according to the configuration topology chosen Panel Resolution Topology Resisto...

Страница 10: ...et 10 of 17 10 14 3 Header Pins Settings Figure 8 J1 Header settings Figure 9 J2 Header settings J1 Header Pin Postion A Factory default position pins 1 2 not linked places TB1 Current sense resistor...

Страница 11: ...i e the two header pins are not shorted together see Figure 5 18 Flip Flop Operation Two beacons can be mounted close to each other to form a flip flop operation where the beacons will flash alternat...

Страница 12: ...Coding for Fault Resistor and Customer EOL Resistor The customer is able to identify the resistor values chosen on purchase from the product code This is represented by the last two characters BEXBG1...

Страница 13: ...n in figure 12 Fig 13 Cover and Guard Fixtures 23 Maintenance Overhaul and Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accorda...

Страница 14: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 14 of 17...

Страница 15: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 15 of 17 1...

Страница 16: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 16 of 17...

Страница 17: ...Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH sales e 2 s com Tel 44 0 208 743 8880 www e 2 s com Fax 44 0 208 740 4200 Document No D197 00 112 IS Issue B 16 06 17 Sheet 17 of 17 1...

Страница 18: ...2011 Directive 2011 65 EU Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS The product and all the components contained within it are in accordance wi...

Отзывы: