European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. IS 2461-P        Issue E       13-01-10                           Sheet 1 of 4

 

INSTRUCTION MANUAL (ATEX / IECEx) 

BExBG15E and BExBG10E   

Flameproof / Increased Safety Xenon Beacons 

For use in Flammable Gas and Dust Atmospheres

 

 
 
 
 
 
 

1)  Introduction 

 

The  BExBG15E  and  BExBG10E  beacons  are  flameproof 
beacons which are certified to meet the requirements of the 
ATEX  directive  94/9/EC  and  the  IECEx  scheme.  The 

beacons  produce  synchronised  visual  warning  signals  and 
can be used in hazardous areas where potentially flammable 

gas and dust atmospheres may be present. The BExBG15E 
has a flash energy level of 15 joules and the BExBG10E has 

a flash energy level of 10 joules. The beacons can be used in 
Zone 1 and Zone 2 areas with gases in groups IIA, IIB and 

IIC  and  Temperature  Classifications  of  T1,  T2,  T3  and  T4. 
The  beacons  can  also  be  used  in  the  temperature 
classification  T5,  if  the  upper  ambient  temperature  is 

restricted  to  +40ºC.

 

The  units  can  be  used  in  Zone 21  and 

Zone 22 areas for combustible dusts and have an IP rating of 

IP 66 and a surface temperature of T125ºC based on max Ta 
of +70°C.  

 

2)  Marking 

 

All  units  have  a  rating  label,  which  carries  the  following 
important information:- 
 
Unit Type No.    

BExBG15E and BExBG10E

 

 
Input Voltage:    DC Units    24V or 48V or 12V (10J only) 

            AC Units    230V or 115V 

 

Codes:    

Ex de T4 for Ta –50ºC to +70ºC 

 

Ex de T5 for Ta –50ºC to +40ºC

 

       

Ex tD A21 T125ºC based on max. Ta of +70ºC 

 

Certificate No’s

    KEMA 00ATEX2006 

 

 

IECEx KEM 10.0002 

 

 

        

 

 

 

 

 

“Warnings”

 

 

DO NOT OPEN WHEN AN EXPLOSIVE  

                             GAS OR DUST ATMOSPHERE IS PRESENT 
 

      COVER BOLTS CLASS A4-80 

 
         

 USE HEAT RESISTING CABLES AND CABLE GLANDS 

          

   (Rated 110ºC) AT AMB. TEMPERATURES OVER 40ºC 

 

Year of Construction /  
Serial No.       

 

 i.e.  

10 / 1DB53000001 

 
 

 
 
 
 
 
 

3) 

Type Approval Standards

 

The  beacons  have  EC  Type  Examination  and  IECEx 

certificates issued by KEMA and have been approved to the 
following standards:- 

 

EN60079-0:2006   IEC60079-0:2004 (Ed4)

      

General Requirements

 

EN60079-1:2007   IEC60079-1:2007

 

(Ed6)

        Flameproof Enclosure ‘d’ 

EN60079-7:2003   IEC60079-7:2001 (Ed3)       

Increased Safety ‘e’

 

EN61241-0:2006   IEC61241-0:2004 (Ed1)       Dust General 

          Requirements 

EN61241-1:2004   IEC61241-1:2004 (Ed1)       Dust Enclosures tD 

 

4) 

Installation Requirements

 

The beacons must be installed in accordance with the latest 
issues  of  the  relevant  parts  of  the  EN60079  and  IEC60079 
standards  –  Selection,  Installation  and  maintenance  of 

electrical  apparatus  for  use  in  potentially  explosive 
atmospheres  (other  than  mining  applications  or  explosive 

processing and manufacture):- 
 

EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 

EN60079-10:2003

   

Classification of Hazardous Areas

 

IEC60079-10:2008 (Ed1) 

 

The installation of the units must also be in accordance with 
any  local  codes  that  may  apply  and  should  only  be  carried 

out  by  a  competent  electrical  engineer  who  has  the 
necessary training. 

 

5) 

Zones, Gas Group, Category and Temperature 
Classification 

The BExBG15D and BExBG10D beacons have been certified 
Ex de IIC T4 for Ta –50ºC to +70ºC and Ex de IIC T5 for Ta –

50ºC to +40ºC for gas and Ex tD A21 IP66 T125ºC based on 
max.  +70ºC  for  dust.  This  means  that  the  units  can  be 

installed in locations with the following conditions:- 
 

Area Classification Gas: 

 

Zone 1 

Explosive  gas  air  mixture  likely  to  occur  in 
normal operation. 

Zone 2 

Explosive  gas  air  mixture  not  likely  to  occur, 
and if it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

Group IIC 

Hydrogen and Acetylene 

  

Temperature Classification: 

 

T1 

400

o

 C  

T2 

300

o

 C 

T3 

200

o

 C 

T4 

135

o

 C 

 

T5 

100

o

 C 

Amb. +40

o

 C 

0518 

II 2G/D 

Epsilon x: 
Equipment Group and 
Category: 

CE Marking 
Notified Body No. 