10
Pin
Cross
section
Name
Description
29
24-16AWG
INPUT#11
Analogue 0 – 32V
30
24-16AWG
INPUT#12
Analogue 0 – 32V
31
24-16AWG
SENSOR GND
Sensor mass, protected
32
24-16AWG
WARNING AND RESET SW Error output for LED against ground, for manual reset connect to ground
33
24-16AWG
POWER IN (+ve)
B
34
24-16AWG
Power ground
Battery -
35
24-16AWG
Power ground
Battery -
36
24-16AWG
Power ground
Battery -
37
24-16AWG
Power ground
Battery -
38
24-16AWG
Power ground
Battery -
39
24-16AWG
Power ground
Battery -
The SCS1000-16LS-AL is protected against false polarization at the main connection and load outputs.
4.2 Intelligent power distribution SCS3000-...
The SCS3000 modules are suitable for a centralised system deployment and replace different individual modules with only one
device, which combines logic and power distribution. The SCS3000 modules have up to 5 H-bridges, PWM capable outputs, 3
CAN channels and an Ethernet connection for configuration and live diagnosis.
The SCS3000 is available in four versions, each of which differs in the number of load outputs. The SCS3000-64, SCS3000-48 and
SCS3000-34 with 64, 48 or 34 load outputs are pin compatible for simple system extensions.
The SCS3000-16 comprises the same technical features as the SCS3000 versions with more channels and is suitable for small
system architectures due to its 16 load outputs and the more compact design.
4.2.1 Dimensions of the SCS3000-16
Figure 4: Dimensions of the SCS3000-16
136.9
47.6
24.7
10.8
142.3
179
4xM4
132.8
95
95
25.45
11.55
90.25