E-Stim Systems ABox Скачать руководство пользователя страница 1

 

ABox

 

Audio Based Electro Stimulation Control Unit 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User Manual 

Issue 3.3 April 2010 

  

Содержание ABox

Страница 1: ...ABox Audio Based Electro Stimulation Control Unit User Manual Issue 3 3 April 2010 ...

Страница 2: ...Monitoring 9 Frequency Response 9 Ideal Levels 9 USING THE ABOX 10 Internal Microphone 10 CAUTION 11 USER CONTROLS 12 Power Switch 12 Input Selector Switch 12 Microphone sensitivity Control 12 Output Level Control 13 Inputs 13 Outputs 13 ACCESSORIES 14 ADDITIONAL NOTES 14 Storage 14 Cleaning 14 SPECIFICATIONS 15 PROBLEMS 16 CERTIFICATE OF CONFORMITY 17 US Regulatory Wireless Notice 17 European Uni...

Страница 3: ...3 Copyright Notice 17 ...

Страница 4: ...t via headphones not supplied Instant and simple stepless control of maximum output level Switched mode voltage generation no bulky transformers Hours of fun from a single PP3 battery Single channel dual output allows the use of unipolar and bipolar electrodes Current limited AC output to ensure complete safety and avoid the possibility of electrode polarisation SAFETY WARNING DO NOT CONNECT THE E...

Страница 5: ...5 OPERATION ...

Страница 6: ... drive your subject wild with just the power of your voice The ability to change the nature of the output just by changing the level and tonal qualities of your voice is a powerful addition to any game The old adage Silence in Golden brings a new meaning when the ABox is used in a BDSM environment Audio Stimulation Solo players will appreciate the stereo input Select your favorite Stim track plug ...

Страница 7: ...y but ensure the polarity is correct before attempting connection 4 Place the battery into the unit and replace the battery compartment cover The cover is fitted with two tabs which insert into the lower half of the case first then the top half of the cover will then clip into position 5 Turn the unit over The unit is now ready for operation Please note we do NOT recommend the use of standard re c...

Страница 8: ...g the microphone sensitivity using the control will allow you to cater for various ambient sound conditions Battery Low Condition If the 25 LED glows when there is no sound input present then this is an indication that the battery voltage is low A low battery will result in lower output levels together with reduced microphone sensitivity Testing Stereo input Using the supplied stereo connection ca...

Страница 9: ... human body does not respond to E Stim Signals above 6Khz audio signals with a substantial high frequency component may not always produce the result that you would expect For the same reason low frequency signals below 50Hz will be poor sources for stimulation Ideal Levels The ideal input level in both the microphone and stereo input modes should result in the maximum input LED flashing from time...

Страница 10: ... to feel a slight tingling sensation from the electrode site If you or your subject experiences any pain or discomfort then stop using immediately If necessary use lubrication as any E Stim device is potentially capable of causing burning when used on sensitive and or small contact areas at high output levels Experiment Only with experience with you get the most out of your ABox You will find that...

Страница 11: ...ly capable of causing burning when used on sensitive and or small contact areas at high output levels DO NOT SHORT CIRCUIT the output DO NOT attempt to open the control box High voltages are present even when the unit is switched off and there are no user serviceable parts inside Opening the control box will invalidate your guarantee The connection cables will be come detached from the E Stim ABox...

Страница 12: ...adphone and two outputs encompassing the dual output single channel output system Power Switch A two position slide switch is mounted on the left side of the unit Slid towards the top of the ABox the unit is switched on slid towards the bottom of the unit it is switched off The power status of the unit is indicated by the position of the switch and the power on LED Input Selector Switch A two posi...

Страница 13: ...levels Use of a headphone will load the input and may affect the input levels The headphone does not operate when the input selector switch is in the MIC position Outputs Connection to electrodes is via two 3 5mm mono jack sockets on the top of the unit Ensure the unit is switched off before inserting or removing the connection jacks to eliminate the possibility of either inadvertent electric shoc...

Страница 14: ...nnection to an input source Other accessories are available For more information visit our website at http www e stim co uk Additional Notes Storage In the event that the E Stim Systems ABox unit is not going to be used for a period of time always remove the battery to avoid any possibility of damage being caused by battery leakage Cleaning DO NOT use solvents to clean the ABox unit A gentle wipe ...

Страница 15: ... Line In Controls Slide switches for Power On Off and Input Selector Rotary controls for adjustment of Microphone sensitivity and Output Level Output Waveform High Voltage current limited pulsed AC Power Supply Standard 9 Volt Alkaline PP3 Battery Life Variable dependent on load and input but estimated at around 8 hours with continuous use Dimensions approx 145mm x 80mm x 50mm Weight with battery ...

Страница 16: ...rts and labour against failure caused by manufacturing defects for a period of 12 months from date of purchase SAFETY WARNING DO NOT CONNECT THE E Stim Systems ABox OR ANY ELECTRICAL DEVICE TO ANY LOCATION ABOVE THE WAIST ACROSS THE ARMS COUNTS AS ABOVE THE WAIST BUT ESPECIALLY DO NOT CONNECT ACROSS THE HEART CHEST NECK OR HEAD DO NOT USE IF FITTED WITH A PACEMAKER OR ARE PREGNANT REMEMBER YOU USE...

Страница 17: ...opean Union Notice Products bearing the CE marking comply with the R TTE Directive 1995 5 EC EMC Directive 89 336 EEC and the Low voltage Directive 73 23 EEC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European norms in parentheses are the equivalent international standards and regulations EN 55022 CISPR 22 Electromagnetic...

Страница 18: ...18 Page intentionally left blank ...

Страница 19: ...19 Page intentionally left blank ...

Страница 20: ...20 Page intentionally left blank ...

Отзывы: