10. Troubleshooting 
 

Symptom 

Operating mode 

Causes 

Repair 

Power supply voltage < 11 V 

Check power supply 

Enable not active 

Check level at pin 14 

Set value 0 V 

Check set value 

Current limitation adjusted too low  Check potentiometer adjustment 

Imax 

Speed range too low 

Check potentiometer adjustment 
nmax 

Wrong operation mode 

Check jumper setting 

Bad connections 

Check connectors 

Motor 
does not 
turn 

All 

Wrong wiring 

Check wiring 

Encoder mode 

Encoder signals 

Check signals and sequence 

Tacho mode 

Tacho signals 

Check voltage and polarity 

No speed 
control 

 

 

 

 
 
 

11. Dimensions 
 

4 x 4,5

80

100

12

104

117

1,5
3,0

100

94

90

82

37

40

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15
16
17

18
19
20
21
22
23
24
25

26
27
28

 

 

12. Versions of Text 

 
V 0.9 (10/02) preliminary issue  

Содержание SCA-LE-30-03

Страница 1: ...ds of mounting it therefore a fast and easy integration is provided Screw terminals and a durable controller design allow a fast and straightforward commissioning Contents 1 Safety notes 1 2 Specifica...

Страница 2: ...quirements with standard EN 61800 3 1996 if the following directions are observed usage of a zinc plated mounting plate well connected to earth mounting of the drive by usage of toothed washers usage...

Страница 3: ...ich is located on the upper side of the drive Both sections have their own PCB and are not connected internally 3 1 Power stage section Terminal numbers 1 to 14 The power stage section of this drive i...

Страница 4: ...lue input is connected to an differential amplifier Input voltage range 10 V 10 V Input impedance 100 kOhm Definition of polarity positive set value Set value Set value negative set value Set value Se...

Страница 5: ...on DO NOT connect Vcc and Power GND to the outputs Motor or Motor 4 2 Outputs 4 2 1 Auxiliary voltage output Enable V 13 The auxiliary voltage output Enable V provides a low resistant connection to pi...

Страница 6: ...tion When the motor is connected in the right way it should turn clockwise at a positive output voltage Otherwise swap the motor lines to ensure that the motor is running clockwise at a positive volta...

Страница 7: ...nge low signal 0 V 5 5 V Input voltage range high signal 13 0V 24 V 5 1 4 Vcc 26 5 1 5 Power GND 25 Power supply connector The encoder section of this drive has to be connected to DC Power supply volt...

Страница 8: ...an encoder feedback are described in the manual SCA LE 30 03 6 2 Selection of Input for Set Value Jumper 5 6 J5 J6 Via Offset Pot Via Ext Pot Via Set Value 6 3 Selection of maximum input frequency of...

Страница 9: ...triebstechnik mbH Zettachring 2 D 70567 Stuttgart Germany Tel 49 0 711 7221535 Fax 49 0 711 7221548 E mail mgmt e motion controls com 6 4 Location of Jumpers J9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 151617...

Страница 10: ...y 11 30 VDC Motor Tacho Tacho Set value Set value Reference Gnd Signal Enable In option see manual Gnd Power Gnd Tacho out Encoder B Encoder A Encoder A 28 27 26 25 24 23 22 21 20 19 18 17 16 15 Encod...

Страница 11: ...iary voltage output enable V 13 and a potential free switch no Enable V 14 13 Enable In 8 2 Input for Set Value The set value for the speed can be set on three different ways 8 2 1 Input for set value...

Страница 12: ...w 9 3 Presetting of potentiometers Original delivered servo amplifiers are adjusted to uncritical values and for easy adjustment by the user 9 4 Adjustment 1 Adjust max set value e g 10 V and turn pot...

Страница 13: ...lue Current limitation adjusted too low Check potentiometer adjustment Imax Speed range too low Check potentiometer adjustment nmax Wrong operation mode Check jumper setting Bad connections Check conn...

Отзывы: