e-Flame USA EF-BLT13-36 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

WALL MOUNT ELECTRIC FIREPLACE  

EF-BLT13-36  

 

EF-BLT13-42 

EF-BLT13-50 

 

EF-BLT13-60 

 

OWNERS MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

NO VENTILATION REQUIRED 

PRODUCES SAFE AND EFFICIENT HEAT 

PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 

120-VOLT / 1300-WATT 

SAVE THIS MANUAL FOR FUTURE USE 

Содержание EF-BLT13-36

Страница 1: ...REPLACE EF BLT13 36 EF BLT13 42 EF BLT13 50 EF BLT13 60 OWNERS MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 120 VOLT 1300 WATT SAVE THIS MANUAL FOR FUTURE USE ...

Страница 2: ... curtains at least 3 feet away from the front of the heater and keep them away from the sides and rear of heater as well 3 Extreme caution is necessary when any heater is used by or near children and whenever the heater is left operating and unattended 4 Do not operate any heater with a damaged cord or plus or after the heater has malfunctioned or has been dropped or damaged in any manner Return h...

Страница 3: ...y a motor It is normal for this motor to at least make some noise as it slowly rotates to create the beautiful flame effect Some rooms with more or less furnishing may result in varying noise amplification 19 Every effort has been made to ensure packing materials are kept outside of the plastic bag which covers your heater in the box There is a possibility that some packing may have lodged into th...

Страница 4: ...it operates properly To do this plug the unit s power supply cord into a 120 volt grounded outlet BEFORE YOU INSTALL 1 Select a location that is not exposed to moisture or dust and is away from high traffic locations and away from objects that may catch fire or potentially block electric fireplace s openings such as drapes pillow furniture textiles etc 2 For the best effect install the fireplace o...

Страница 5: ... screw the brackets to the appliance with mounting screws red arrows 1 2 3 Please use care with the outer glass bracket screws 5 Plug in the unit then press the power key on the unit or remote control ensure that the batteries are installed to remote control Next ensure the LED lights are working correctly 6 Press the ON OFF button to turn off the unit and then pull the plug from the socket Store ...

Страница 6: ...d the bracket and mounting screws red arrows 1 2 3 2 Carefully remove the glass 4 3 Remove the log set and adjust the screws red arrow 5 6 7 4 Arrange the crystals where you removed the log set 8 5 Cautiously reattach glass with bracket screws 1 2 3 4 5 6 7 8 9 ...

Страница 7: ...ireplace Leave a gap of at least 1 4 inch around the edge of the unit Any new wiring must be done in compliance with local and national codes and any other applicable regulations WARNING To prevent contact with sagging or loose insulation the electric fireplace must not be installed against a vapor barrier or exposed to insulation Overheating could occur and a fire may result from this Do not atte...

Страница 8: ...l in located on the right corner of the glass MASTER SWITCH The master switch controls the power supply to the electric fireplace Turn the switch to I to connect the power and turn the switch to O to turn the power off There will be a chiming sound when turning to I POWER ON OFF Touch the button once flame will light up to turn the power on for all functions Touch the button again to turn all func...

Страница 9: ...te the heater s fan will continue to run for a short time after turning unit off and will turn off automatically after the heater has cooled down TIMER This fireplace is equipped with a timer ranging from 1 hour to 9 hours and can be programmed in 1 hour increments Touch the button once for every 1 hour increment Do not leave the electric fireplace unattended REMOTE CONTROL FEATURES Install the CR...

Страница 10: ...e for instructions Flame sputters Flame s motor is defective Call Customer Service for instructions Remote control does not work Low battery Master switch is in OFF position Change the battery for remote control Check to make sure the master switch is turned on Circuit breaker trips or fuse blows when the unit is on Improper circuit current rating Call Customer Service for instructions Heater does...

Страница 11: ...he outlet Use a vacuum or duster to keep heater and vent area clean from dust and dirt The exterior of the electric fireplace should be cleaned with a damp cloth or duster Do not use any abrasive cleaners liquid sprays or any other clear that may scratch the surface ...

Страница 12: ...wer source water damage damage caused from the electric fireplace being used outdoors damage caused from the electric fireplace being used for excessive periods of time damage caused by the electric fireplace being used in any commercial application damage from use as a primary heat source other misuse and abuse not specifically listed herein This product is not intended to be used as a primary he...