PROGRAMMING
3-18
November 2001
Part No. 001-7240-001
Conventional Group Programming Screen
Parameter
Description
Group
Number
This drop-down list selects the group to be added or edited in the screen.
Alpha Tag This specifies the eight-character alpha tag that is displayed when the group is selected.
Tx Option Always = Tx enabled, TDOB (Transmit Disable On Busy) disabled
Disable Busy = Tx and TDOB enabled, no transmit with carrier even with valid Call Guard
On Valid CG = Tx and TDOB enabled, transmit with carrier allowed only with valid Call Guard
Disabled = Tx disabled (receive-only channel). See Sections 2.4.10 and 2.11.3.
Tx Call
Guard Type
Selects the type of transmit Call Guard squelch control as Tone (CTCSS), digital (DCS), inverted digital, or
none (carrier). See Section 2.11.6.
Tx Call
Guard Code
If tone or digital encode Call Guard squelch was selected above, selects the tone frequency or digital code that
is transmitted. These tones and codes are listed in Table 3-6.
Rx Call
Guard Type
Selects the type of receive Call Guard squelch control as Tone (CTCSS), digital (DCS), inverted digital, or none
(carrier). See Section 2.11.6.
Rx Call
Guard Code
If tone or digital decode Call Guard squelch was selected above, selects the tone frequency or digital code that
must be decoded to receive a call. These tones and codes are also listed in Table 3-6.
Add to Grp
Scan List
Selects the default scan list status of the group. This programming can be overridden by the scan list A/D key if
available (Section 2.6.7).
Encryption
Available
Encryption is currently not available.
Activate Call
Light
Selects if the call indicator is activated when a call is received on the group (Section 2.4.2).
Talk-Around Selects if the talk-around mode is selected when transmissions are made on the group (Section 2.11.5).
Delayed
Proceed Tone
Selects if the proceed tone is delayed by the time programmed on the Timing Parameters screen when a call is
placed on the group (Section 2.4.9).
Send
Turn-off
Selects if the Call Guard turn-off code is sent when the PTT switch is released (Section 2.11.6).
Table 3-4 Group Programming Screen Description (Continued)