INTRODUCTION AND OPERATION
1-5
September 1994
Part No. 001-2008-300
Ground
J501 is connected to ground for test equipment
when monitoring voltage test point J502.
A/D Level Test Point
J500 provides a test point to monitor audio and
data levels, AC fail and thermal sensor.
Power Supply On/Off Switch
S508 turns the power supply DC voltages on and
off from the front of the repeater.
Power Indicator
CR501 indicates the +5V supply is at normal
level and applied to the IAC. CR524 indicates -5V
supply is at normal level and applied to the IAC.
CR523 indicates the +15V accessory supply is at nor-
mal level. CR525 indicates that the +15V supply is at
normal level and applied to the IAC.
Xmit Indicator
Indicates that the Universal Station’s transmitter
is keyed by the logic.
1.11.3 POWER SUPPLY
The power supply is sealed and the line and sup-
ply fuses are inside. If a supply fuse opens, the power
supply must be removed and opened for repair (see
Section 2.4 and 8.5). Refer to the power supply ser-
vice manual 004-2000-810.
Standby Battery Jack
This provides a connection point for a +24V DC
standby battery. Current is drawn from the battery
only when the power supply output voltage is lower
than the battery voltage. A trickle charge switch on
the supply ensures that the battery is fully charged.
Disable this switch when a separate battery charger is
used (see Section 2.5).
Figure 1-2 UNIVERSAL STATION CARDS
IAC
J502
J501
J500
XMIT
CWID
+15V
GND
TP
S508
RF INTERFACE
BOARD
EXCITER/RECEIVER
PA
J103
J100
J1
CR4
DS1
S1
J102
J101
J104
TPI
+5V
-5V
+15V
+15V
ACC
ACTIVE
HI PWR
R164
CR5
CR3