SYSTEM RACK
4-24
2. All PTMs should be installed and configured as
follows:
Switch
Sections Closed
Sections Open
S5, S7
3,4,5,6,7
1,2
S6, S8
2,3,6
1,4,5,7,8
3. Select one of the 8 Backplane boards for measuring.
Measurements can be made on any of the
64-pin connectors on the Backplane selected.
4. All measurements should be referenced to ground
(pins 9, 10, 41 or 42) unless otherwise noted.
5. All test readings should be within 5% of the
following specifications:
Pins
Ohms
16/48
37.5
17/49
37.5
18/50
37.5
19/51
75.0
20/52
37.5
21/53
37.5
22/54
100 (measured to +5V DC*)
23/55
37.5
24/56
100 (measured to +5V DC*)
* Pins 11, 12, 43 or 44.
6. On the top Backplane board, the following measure-
ments should be referenced to ground (pins 9, 10, 41
or 42).
Center Pin of
Ohms
J5
37.5
J6
37.5
J23
19.2
J24
19.2
NOTE: The four readings should be ±1 ohm from
the test specifications.
7. Test is completed.
Disconnect the cables from the Call Processor.
Содержание 3000 SERIES
Страница 2: ......
Страница 12: ...TABLE OF CONTENTS viii TABLE OF CONTENTS CONT D This page intentionally left blank ...
Страница 20: ...3000 SERIES SWITCH 2 6 This page intentionally left blank ...
Страница 26: ...ARCHITECTURE 3 6 This page intentionally left blank ...
Страница 58: ...CALL PROCESSOR 5 4 This page intentionally left blank ...
Страница 76: ...BASIC BOARD MODULE BBM 7 14 This page intentionally left blank ...
Страница 83: ...CHANNEL INTERFACE MODULE CIM 8 7 Figure 8 3 SUMMATION BOARD ALIGNMENT POINTS DIAGRAM ...
Страница 84: ...CHANNEL INTERFACE MODULE CIM 8 8 This page intentionally left blank ...
Страница 88: ...CONVENTIONAL CHANNEL MODULE CCM 9 12 This page intentionally left blank ...
Страница 92: ...DISPATCH CHANNEL MODULE DCM 10 4 This page intentionally left blank ...
Страница 100: ...DISPATCH INTERFACE MODULE DIM 11 8 This page intentionally left blank ...
Страница 142: ...TELEPHONE INTERFACE MODULE TIM 14 32 This page intentionally left blank ...
Страница 146: ...VOTER DIAGNOSTICS MODULE VDM 15 4 This page intentionally left blank ...
Страница 148: ...POWER TERMINATION MODULE PTM 16 2 Figure 16 1 POWER TERMINATION MODULE ALIGNMENT POINTS DIAGRAM ...
Страница 156: ...VOICE TONE MODULE VTM 18 4 This page intentionally left blank ...
Страница 164: ...WIDE AREA MODULE WAM 19 8 This page intentionally left blank ...
Страница 174: ...CONVENTIONAL PATCH MODULE CPM 21 4 This page intentionally left blank ...
Страница 178: ...POWER SUPPLY 22 4 Figure 22 6 POWER SUPPLY DRAWER ...
Страница 196: ...INTERCOM 24 2 This page intentionally left blank ...
Страница 200: ...ERROR MESSAGES A 4 This page intentionally left blank ...
Страница 214: ...Part Number 001 3139 005 10 03 Printed in U S A ...