4-1
SYSTEM RACK
SECTION 4 SYSTEM RACK
4.1 TWO SHELF 3000 SERIES SWITCH
The system rack is a framework for modules that
consists of up to two shelves with thirteen slots per
shelf. In each shelf, twelve slots are for function
modules and one slot is reserved for the power
module. The power supplies for the shelves are
located in the lower portion of the rack framework.
The framework also provides support for interconnec-
tion wiring, routed between shelves, and external
devices.
4.1.1 POWER CONSUMPTION
The following tables shows the average voltage,
current and power for each supply voltage per card
(based on loading of 24 cards).
Total watts including TIM-DID is 5.74W.
Excluding the TIM-DID provides a total of 4.3W for
normal modules. The total wattage of the terminal is
found by multiplying the wattage of a module by the
number of modules.
Total Watts x No. of Modules = Terminal Power
The wattage required by the power supply is
found by dividing the total wattage of the terminal by
the efficiency of the power supply (0.7).
Terminal Power
÷
0.7 = Wattage of Power Supply
The BTUs per hour are found by multiplying a known
value (3.6) by the wattage required by the power
supply.
3.6 x Wattage of Power Supply = Btu/Hr.
EXAMPLE:
4.3W x 12 = 51.6W
51.6W
÷
0.7 = 73.7W
3.6 x 73.7W = 265 Btu/Hr
4.1.2 EQUIPMENT REQUIRED
1. Digital Multimeter, voltmeter resolution to 0.001V.
2. Transmission test set, HP 3551A.
3. IBM NT compatible computer, with Call Processor
Software.
4. Two CIMs (023-3039-035)
Table 4-1 AVERAGE VOLTAGE/CURRENT/
POWER
Voltage
Current
Power
+5V DC
0.50A
2.50W
+12V DC
0.10A
1.20W
-12V DC
0.05A
0.60W
-48V DC
0.03A*
1.44W
Total
5.74W
* DIDs only.
Содержание 3000 SERIES
Страница 2: ......
Страница 12: ...TABLE OF CONTENTS viii TABLE OF CONTENTS CONT D This page intentionally left blank ...
Страница 20: ...3000 SERIES SWITCH 2 6 This page intentionally left blank ...
Страница 26: ...ARCHITECTURE 3 6 This page intentionally left blank ...
Страница 58: ...CALL PROCESSOR 5 4 This page intentionally left blank ...
Страница 76: ...BASIC BOARD MODULE BBM 7 14 This page intentionally left blank ...
Страница 83: ...CHANNEL INTERFACE MODULE CIM 8 7 Figure 8 3 SUMMATION BOARD ALIGNMENT POINTS DIAGRAM ...
Страница 84: ...CHANNEL INTERFACE MODULE CIM 8 8 This page intentionally left blank ...
Страница 88: ...CONVENTIONAL CHANNEL MODULE CCM 9 12 This page intentionally left blank ...
Страница 92: ...DISPATCH CHANNEL MODULE DCM 10 4 This page intentionally left blank ...
Страница 100: ...DISPATCH INTERFACE MODULE DIM 11 8 This page intentionally left blank ...
Страница 142: ...TELEPHONE INTERFACE MODULE TIM 14 32 This page intentionally left blank ...
Страница 146: ...VOTER DIAGNOSTICS MODULE VDM 15 4 This page intentionally left blank ...
Страница 148: ...POWER TERMINATION MODULE PTM 16 2 Figure 16 1 POWER TERMINATION MODULE ALIGNMENT POINTS DIAGRAM ...
Страница 156: ...VOICE TONE MODULE VTM 18 4 This page intentionally left blank ...
Страница 164: ...WIDE AREA MODULE WAM 19 8 This page intentionally left blank ...
Страница 174: ...CONVENTIONAL PATCH MODULE CPM 21 4 This page intentionally left blank ...
Страница 178: ...POWER SUPPLY 22 4 Figure 22 6 POWER SUPPLY DRAWER ...
Страница 196: ...INTERCOM 24 2 This page intentionally left blank ...
Страница 200: ...ERROR MESSAGES A 4 This page intentionally left blank ...
Страница 214: ...Part Number 001 3139 005 10 03 Printed in U S A ...