User Manual EE160 Humidity and Temperature Sensor for HVAC Applications

The steps recommended by the manufacturer for installation, inspections and maintenance work must 

be observed and carried out for the safety of the user and for the functionality of the equipment.

Unauthorized product modification leads to loss of all warranty claims. This may be accomplished only 

with an explicit permission of E+E Elektronik

®

!

1.2.3  Mounting, Start-up and Operation

The EE160 humidity and temperature sensor has been produced under state of the art manufacturing 

conditions, has been thoroughly tested and has left the factory after fulfilling all safety criteria. The 

manufacturer has taken all precautions to ensure safe operation of the device. The user must ensure 

that the device is set up and installed in a manner that does not have a negative effect on its safe 

use. The user is responsible for observing all applicable safety guidelines, local and international, with 

respect to safe installation and operation on the device. This user manual contains information and 

warnings that must be observed by the user in order to ensure safe operation.

 

ƒ

Mounting, start-up, operation and maintenance of the device may be performed by qualified staff 

only. Such staff must be authorized by the operator of the facility to carry out the mentioned activities.

 

ƒ

The qualified staff must have read and understood this user manual and must follow the instructions 

contained within.

 

ƒ

All process and electrical connections shall be thoroughly checked by authorized staff before putting 

the device into operation.

 

ƒ

Do not install or start-up a device supposed to be faulty. Make sure that such devices are not 

accidentally used by marking them clearly as faulty.

 

ƒ

A faulty device may only be investigated and possibly repaired by qualified, trained and authorized 

staff. If the fault cannot be fixed, the device shall be removed from the process.

 

ƒ

Service operations other than described in this user manual may only be performed by the 

manufacturer. 

1.3  Environmental Aspects

Products from E+E Elektronik® are developed and manufactured in compliance with all relevant  

environmental protection requirements. Please observe local regulations for the device disposal.

For disposal, the individual components of the device must be separated according to local recycling 

regulations. The electronics shall be disposed of correctly as electronics waste.

2  Scope of Supply

Model

EE160 Wall mount 

(Type T1)

EE160 Duct mount 

(Type T2)

Additionally for all EE160  

with RS485 interface

EE160 Humidity and Temperature Sensor 

according to order code

Cable gland

Mounting kit

Mounting flange

Inspection certificate according to  

DIN EN 10204-3.1

Quick Guide - EE160 RS485 Setup

3  Product Description

Содержание EE160

Страница 1: ...BA_EE160 v2 0 Modification rights reserved User Manual EE160 Humidity and Temperature Sensor for HVAC Applications...

Страница 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Страница 3: ...2 Scope of Supply 5 3 Product Description 6 3 1 General 6 3 2 Dimensions 6 3 3 Electrical Connection 6 4 Setup and Adjustment 7 4 1 EE PCS Product Configuration Software 8 4 2 Address Setting 8 4 3 B...

Страница 4: ...al Safety Instructions The device and mainly the filter cap shall not be exposed to unnecessary mechanical stress When replacing the filter cap make sure not to touch the sensing elements The device m...

Страница 5: ...by the operator of the facility to carry out the mentioned activities The qualified staff must have read and understood this user manual and must follow the instructions contained within All process a...

Страница 6: ...the E E sensor coating ensure long term stable and accurate measurements The user can set the RS485 interface parameters the output scaling and perform one or two point adjustment for RH and T with an...

Страница 7: ...adapter on adapter connected to EE160 and PC no communication with EE PCS flashing communication in progress with EE PCS off adapter not connected to EE160 and PC 4 Setup and Adjustment The EE160 is...

Страница 8: ...cted device 5 Click on the desired setup or adjustment mode from the main EE PCS menu on the left and follow the online instructions of the EE PCS 4 2 Address Setting Address Switch Address Switch Add...

Страница 9: ...firmware version is located in the register address 0x08 bits 15 8 major release bits 7 0 minor release The sensor name is located in register address 0x09 The beforementioned registers can be read o...

Страница 10: ...choice of measurement units metric or non metric is done at the time of ordering see the ordering guide in the EE160 data sheet It is not possible to switch from metric to non metric or vice versa by...

Страница 11: ...eplusecal com Calibration and adjustment by the user Depending on the level of accuracy required the humidity reference can be Humor 20 Humidity Calibrator please see www epluse com Omniport30 handhe...

Страница 12: ...0 mA 10 V RL x 20 mA UV 35 V DC Current consumption typ 4 20 mA output 0 10 V output RS485 24 V DC supply max 40 mA 5 mA 5 mA 24 V AC supply 13 mArms 15 mArms Connection Screw terminals max 1 5 mm2 Ho...

Страница 13: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Отзывы: