Product Manual WS74
__________________________________________________________________________________
Copyright
DZG Metering GmbH, Heidelberger Str. 32, D-16515 Oranienburg
Copies only are allowed authorized by DZG
2/22/2019
Page 15 / 37
6
LCD-Display
Figure 7 LCD
Pos.
Symbol
Explanation
1
First line
Display of billing relevant energy register with 6 digit and 3-digit OBIS Code
2
Second line
INFO line for values not relevant for billing 6 digit with 3-digit OBIS Code
3
OBIS Code
OBIS Code of the displayed energy register
The OBIS Code of the currently active tariff register will be underlined
4
INFO
OBIS Code
and further character
PIn PIN Input
P Power
E demand since last reset
HIS historical values
1d historical value current day and 730 days before
7d historical value current 7 days and 52 weeks before
30d historical value current 30 days and 24 month before
365d historical value current 365 days and 2 years before
5
Energy register
6 digit without decimal and with leading 0
6
6 digit with one decimal without leading 0, right aligned
7
unit
kWh, W, Wh, V, A
8
L1
Display voltage
on: > 80% Un
off: < 60% Un
9
-A +A
Display current energy direction
on: load detected
off: no load
10
Display current energy direction
Import
Export
on: load detected
off: no load
11
- - - -
Current power indication
The bar is moving dependent from the power from the left to the right side.
In case of no load the bars are off.
When load is detected the bar starts to move. A next bar is switched on and the previous
off after 100mWh change of the energy register. To avoid flashing of the bars each bar
has to be switched on for 500ms.
The 100 mWh demand is equal to the demand of a pulse of the test LED (10.000
kWh/imp = 1 imp/100 mWh).
12
Communication for
LMN
Indicating communication, when a LMN-PlugIn is used. It indicates the communication
of the PlugIn on the LMN-Interface side
off: no communication
0,5s on / 0,5s off: communication on layer2
2s on / 1s off: HDLC connect established
on: TLS-channel t a SMGW established
13
Communication
Reserved
14
Communication
Indicating communication, when a communication PlugIn is used.
No.1 on : communication with PlugIn
No.2 reserved
No.3 reserved
Table 7 Display elements