PowerDepot H5B series User Manual
22
If the equation holds after calculation, it means communication between
PowerDepot H5B and PowerDepot H5B is normal.
2. If the PowerDepot H5B ALM light board shows three different colors flash
alternately, it means the communication between PowerDepot H5B is fault.
Table 3-3 Battery& Inverter power matching table
Power of
Hybrid Inverter/
Off-grid Inverter
PowerDepot H5B
Type
System Energy(kWh)
2KW
PowerDepot H5B
5.12
3KW
PowerDepot H5B
5.12
4KW
2*PowerDepot H5B
10.24
5KW
2*PowerDepot H5B
10.24
6KW
2*PowerDepot H5B
10.24
8KW
3*PowerDepot H5B
15.36
Equipment
Use
Charging
a) The battery's long-term continuous charging current
should be ≤0.5C
b) If the battery remaining capacity is empty, please charge it
within 48 hours after the battery is empty.
Discharging
c) The long-term continuous discharge current of the battery
should be ≤0.5C
d) The recommend maximum depth of discharge (DOD)of
Battery PACK is no more than 85%.
3.2.5 Battery parameter settings on the inverter
Max Charging(Bulk) Voltage: 56.5V
Absorption Voltage: 56V
Float Voltage: 55.5V
Shut Down(cut off) Voltage: 48~50V
Shut Down(cut off) SOC: 20%
Restart Voltage: 52V
Max Charge Current:
50A*battery QTY
Max Discharge Current:
50A*battery QTY
Capacity
:
100Ah
3.2.6 Register on the website after installation
After the battery system installation is completed and the running is
normal, you need to log in to the DYNESS official website to register the