![Dynatronix DHP12-1500 Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/dynatronix/dhp12-1500/dhp12-1500_operating-manual_2549220091.webp)
Diamond 36kW Manual
Dynatronix, Inc.
198-1600-00 Rev F
Page 91 of 146
A.6.6 Error Handling Setup Menu
.
.
.
.
.
.
.
.
.
Error Handling
Setup Menu
Enter the error handling setup menu from
the unit setup menu.
Return to Unit Setup
Menu
Numeric error code display is enabled. When a
fault occurs the active run screen will alternate
between its normal view and a numeric error code.
Numeric error code display is disabled. Numeric
error codes can still be viewed from within the
error clear menu.
Do not clear error codes
Clear all active error codes
Do not clear error code 091.1
Clear error code 091.1
Do not clear error code 094.1
Clear error code 094.1
All active error codes are listed. If no error codes
are active then only the “ALL” and the “End”
menu are shown.
NOTE: If the error
condition still exists
after an error code
is cleared the error
code will be set
again.