A.5 Display Select Menu
.
.
.
.
First screen showing ATC
amp hours remaining in the
currently running cycle. If
the currently running cycle
were an RTC controlled
cycle then “RTC” would
be displayed rather than
“ATC”.
Second screen
showing ATC amp
hours remaining in
the currently
running cycle.
Third screen showing
ATC amp hours
remaining in the
currently running cycle.
If the units were amp
minutes then this screen
would show “min”
rather than “Hr”.
Last screen blinking
‘Lo’ to indicate the
lower four digits of the
remaining cycle time
are shown. Rotate the
voltage encoder to
change to ‘Hi’ and
show the upper four
digits.
Pressing the current encoder
displays the cycle preset and
allows direct edit of the setting
(standby only). Rotate the
voltage encoder to select the
upper ‘H’ or lower ‘L’ half of
the preset. Use the current
encoder to change the value.
Expected average current reading. This is the
computed average current based on the current
settings when the power supply is regulating current.
This is the value that is compared to the actual
readings for tolerance checks when the current
tolerance is not zero.
Expected average voltage reading. This is the
computed average voltage based on the voltage
settings when the power supply is regulating voltage.
This is the value that is compared to the actual
readings for tolerance checks when the voltage
tolerance is not zero.
.
.
.
.
.
.
.
.
.
.
.
.
Enter the display select menu from any run screen (meters, totalizer,
cycle, or diagnostics) by pressing and holding both encoder switches
for one second.
Once “diSP” “SEL” is displayed release
both encoder switches.
First screen showing total
amp hours
Second screen showing total
amp hours
Third screen showing total amp
hours. If the units were amp
minutes then this screen would
show “min” rather than “Hr”.
Last Screen, blinking ‘Lo’
to indicate the lower four
digits of the total amp
hours are displayed.
Rotate the voltage encoder
to change to ‘Hi’ and show
the upper four digits.
Pressing the voltage encoder
displays the voltage setting and
enables edit of the voltage setting.
Rotate the voltage encoder to
change digit values, press the
voltage encoder to select digits.
Pressing the current encoder
displays the current setting and
enables edit of the current setting.
Rotate the current encoder to
change digit values, press the
current encoder to select digits.
After the settings are not adjusted
for a short period of time the
display returns to the meter values.
Meter Run
Screen
Totalizer
Run Screen
Cycle Run
Screen
Diagnostic
Run Screen
Voltage and current
meter run screen.
NOTE:
The expected readings
shown in the diagnostics menu can
be helpful when adjusting
tolerance settings for complex
waveforms.
NOTE:
When ramping is enabled
(ramp time > 0) the expected readings
in the diagnostics menu reflect
ramped settings and are zero in
standby mode. The expected readings
update in operate mode as the ramp
progresses.