10.1.3. Restoring the default calibration values
The default calibration values can be restored with the following procedure.
CAUTION:
Restoring the default calibration values will cause any previous calibration values to be
overwritten. To have accurate output levels a calibration must be performed after loading the
default calibration points. Default calibration points are provided as a tool to aid in trouble
shooting and power supply configuration, they are not intended to be used for accurate power
supply operation.
1.
From the “Unit Configuration Menu” rotate the current encoder until the display shows
“CFg” “CAL”. Press the voltage encoder switch to enter the “Calibrate Configuration
Menu”. See
and
A.7.5: Calibrate Configuration Menu
for
more details on menu navigation.
2.
From the “Calibrate Configuration Menu” rotate the current encoder to select the desired
calibration menu.
Select “rd A” for module A (top module). Select “rd b” for module B
(bottom module).
Select “OPt” for the analog option card.
3.
From the calibration menu rotate the current encoder until the display shows “dFLt” on the
bottom display. Press the voltage encoder switch to proceed with loading default
calibration values.
4.
The default calibration confirmation screen shows “dFLt” on the top display and “yES” or
“no” on the bottom display. Rotate the current encoder to select “yES” and press the
voltage encoder switch to load the calibration default values.
5. Proceed with a normal calibration.