![Dynatronix DHP12-1500 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/dynatronix/dhp12-1500/dhp12-1500_operating-manual_2549220018.webp)
Page 18 of 146
198-1600-00 Rev F
5.5. Serial Host Port Connections
The serial host port can be used to monitor and/or control the power supply using the ASCII Host
Protocol (See section
). The serial host port supports a half duplex
RS485 interface. Multiple power supplies can be connected to a single RS485 bus (multi-drop).
Each device on the RS485 bus is individually addressed using the ASCII Host Protocol. If an
RS232 device (such as a PC) will be connected to the host port then an RS232 to RS485
converter module will be required (not included).
5.6. Inverter Control Connections
The remote control is connected to the main power supply inverter with the supplied DB9 cable.
Various standard and custom cable lengths are available from Dynatronix. Only use cables
provided by or specified by Dynatronix. Improper connections or cable lengths and wire gauges
can result in un-reliable operation or damage to the remote control or inverter control.
1
5
9
6
RS485 Connections
1 nc
2 nc
3 nc
4 RS485 Data A
5 nc
6 nc
7 nc
8 RS485 Common
9 RS485 Data B
DB9 female connector on
remote control.
5
1
6
9
Inverter Connections
1 Input Pwr GND
2 Input Pwr GND
3 nc
4 RS485 Data A
5 Input Pwr +15V
6 Input Pwr +15V
7 ISO +15V (RS485)
8 ISO GND (RS485)
9 RS485 Data B
DB9 male connector on
remote control.