![Dynatronix DHP12-1500 Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/dynatronix/dhp12-1500/dhp12-1500_operating-manual_2549220117.webp)
Diamond 36kW Manual
Dynatronix, Inc.
198-1600-00 Rev F
Page 117 of 146
B.1.11
Delimiter Text Disable/Enable Command “i”
@AA.a Sync character (@) and unit address, AA = Unit ID (0 to 99; 0 is a global ID), a = Channel
ID (always 0)
i0
Command character and Type
– 0=read, 1=set, 2=activate(n/a), 3=ack, 4=nak
#1,
Number of fields character and number of fields after the comma, excluding CRC
0,
Delimiter text flag
– 0=disable, 1=enable. Default on power-up is disabled.
txtf
CRC
CRC value in ascii decimal. NOTE: examples show actual CRC values.
crlf
Carriage return and Line feed (0x0D 0x0A)
Example of Delimiter Text Enable/Disable Command:
Disable delimiter text command
@00.0i1#1,0,54321
Enable delimiter text command
@00.0i1#1,1,
54321
Read delimiter text State command.
@12.0i0#0,
54321
ACK response for read delimiter text state command, unit address = 12. Shown with delimiter text
enabled and disabled.
@12.0i3#1,1txtf,
54321
@12.0i3#1,1,
54321
Notes:
1. Delimiter Text setting on power supply power-up is
Disabled
.
2. There is no requirement for the host to send delimiter text if delimiter text is enabled, it is optional.
3.
The channel ID ‘a’ should always be zero.