SD-BOX INSTRUCTION MANUAL, CODE: DYN 81.01.00
Date: 03/03/2020
Version 00
- 17 -
5.3.
ELECTRICAL DIAGRAMS
1 OUTPUT. Normally open (NO) for fault indicator/coil status. This contact is closed if there is
a fault or the coil is activated.
2 OUTPUT. Normally closed (NC) for fault indicator/coil status. This contact is open if there is
a fault or the coil is activated.
3 OUTPUT. Common for fault indicator.
4 OUTPUT. SAFETY LINE: Common safety contact to connect to safety line.
5 No connection.
6 OUTPUT. SAFETY LINE: Normally open contact to connect to safety line.
7-19 No connection.
20 INPUT. External reset. 0 V
21 INPUT. External reset, 24 V. If there is voltage, the reset action is performed.
22 INPUT. Level 1. 0 V
23 INPUT. Level 1. 24 V.
24 INPUT. Level 2. 0 V
25 INPUT. Level 2. 24 V.
26 INPUT. Remote manual rescue, 0 V.
27 INPUT. Remote manual rescue, 24 V. If there is voltage for more than 3 seconds, the manual
or bypass rescue action is performed.
28-31 No connection.
32 INPUT. 24 V
DC
power supply.
33 INPUT. 0 V power supply.
34 INPUT. Bat
35 INPUT. Batteries -
36 No connection.
37 No connection.
38 OUTPUT. Inductive sensor, 0 V power supply.
39 INPUT. Inductive sensor, Detection.
40 OUTPUT. Inductive sensor, 24 V
DC
power supply.
41 No connection.
42 OUTPUT. Coil, 24 V
DC
43 OUTPUT. Coil, 0 V
DC
44-48 No connection.
49 INPUT. Doors, 0 V