Once it has been fitted, and the safety gear’s rollers have been attached to the driving bar’s tripping bars, it
should be checked that both rollers operate simultaneously, controlled by the driving bar.
The minimum force required for tripping the safety gear is 300N.
⚠
The Standard demands that the installation incorporate an AC-15 or DC-13 safety contact as defined in
EN 60947-5-1.
3.3.1 USING DYNATECH’S T-1 DRIVING BAR
Both safety gears may be synchronised by assembling Dynatech’s T-1 driving bar. For more information
concerning T-1 driving bar assembly, please consult its manual: DYN04 – Instructions T-1.
⚠
It is not recommended to exceed a maximum force of 1900 N is not recommended with the governor.
Figure 7: Safety gear synchronisation using the T-1 driving bar
4 INSPECTIONS AND MAINTENANCE
4.4 STORAGE AND SERVICE LIFE
The safety gear should be stored in a cool, dry place. It should be protected from excessive lighting. It should
never be exposed to severe weather conditions.
Storage temperature: 5 - 40ºC
Storage humidity: 15 - 85% without condensation.
The safety gears’ packaging should be clean and dry, so that they can be clearly identified.
It is not permitted to place constant or unbalanced loads on a package, which may cause the package to be
bent, or to allow products to be stacked one on top of the other. When stacking products or packages, the
storage height should take into account their load and stability.
If the criteria established for proper maintenance are observed, the safety gears may have the same service
life as the rest of the installation’s fixed elements provided that their proper functioning is ensured and
controlled. The element’s service life is not affected by grease, dust or dirt due to the shaft’s condition or to
environmental conditions differing from those stated in this manual.