38
Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC VIBRAS
MAINTENANCE
11. Remove seals from the head and install new seals. Repeat for both heads.
Picture 31: Removing the pump head seals
NOTE!
DYNASET recommends replacing the pumping fluid valves at the same
time as the pump seals. READ CHAPTER ”6.4. Replacing seals and intake
12. Install intake valve and head into the body. Repeat for both heads. Read correct
bolt torques from chapter 6.6
Picture 32: Installing the pump heads