HYDRAULIC ROTARY VANE COMPRESSORS
MAINTENANCE
6.11.1. ADJUSTING THE OFF-LOAD PRESSURE IN STANDARD COMPRESSOR
1. Remove air filter and intake filter cover. Loosen the locknut of the servo valve.
2. Tighten the adjusting screw to increase pressure, loosen the adjusting screw to
decrease pressure. Use separate pressure gauge in pressure line when making
the adjustement.
Nominal output pressure
Servo valve’s setting
8 bar
8,5 bar
10 bar
10,5 bar
3. Lock the setting with locknut.
4. Install intake filter cover and air filter.
6.11.2. ADJUSTING THE OFF-LOAD PRESSURE IN O-PE COMPRESSOR
O-PE hysteresis locking nut and pilot valve is set in DYNASET factory, dimension H
default factory setting is 17,50...17,70mm.